Inter- and Intra-Observer Repeatability of Quantitative Whole-Body, Diffusion-Weighted Imaging (WBDWI) in Metastatic Bone Disease

نویسندگان

  • Matthew D. Blackledge
  • Nina Tunariu
  • Matthew R. Orton
  • Anwar R. Padhani
  • David J. Collins
  • Martin O. Leach
  • Dow-Mu Koh
چکیده

Quantitative whole-body diffusion-weighted MRI (WB-DWI) is now possible using semi-automatic segmentation techniques. The method enables whole-body estimates of global Apparent Diffusion Coefficient (gADC) and total Diffusion Volume (tDV), both of which have demonstrated considerable utility for assessing treatment response in patients with bone metastases from primary prostate and breast cancers. Here we investigate the agreement (inter-observer repeatability) between two radiologists in their definition of Volumes Of Interest (VOIs) and subsequent assessment of tDV and gADC on an exploratory patient cohort of nine. Furthermore, each radiologist was asked to repeat his or her measurements on the same patient data sets one month later to identify the intra-observer repeatability of the technique. Using a Markov Chain Monte Carlo (MCMC) estimation method provided full posterior probabilities of repeatability measures along with maximum a-posteriori values and 95% confidence intervals. Our estimates of the inter-observer Intraclass Correlation Coefficient (ICCinter) for log-tDV and median gADC were 1.00 (0.97-1.00) and 0.99 (0.89-0.99) respectively, indicating excellent observer agreement for these metrics. Mean gADC values were found to have ICCinter = 0.97 (0.81-0.99) indicating a slight sensitivity to outliers in the derived distributions of gADC. Of the higher order gADC statistics, skewness was demonstrated to have good inter-user agreement with ICCinter = 0.99 (0.86-1.00), whereas gADC variance and kurtosis performed relatively poorly: 0.89 (0.39-0.97) and 0.96 (0.69-0.99) respectively. Estimates of intra-observer repeatability (ICCintra) demonstrated similar results: 0.99 (0.95-1.00) for log-tDV, 0.98 (0.89-0.99) and 0.97 (0.83-0.99) for median and mean gADC respectively, 0.64 (0.25-0.88) for gADC variance, 0.85 (0.57-0.95) for gADC skewness and 0.85 (0.57-0.95) for gADC kurtosis. Further investigation of two anomalous patient cases revealed that a very small proportion of voxels with outlying gADC values lead to instability in higher order gADC statistics. We therefore conclude that estimates of median/mean gADC and tumour volume demonstrate excellent inter- and intra-observer repeatability whilst higher order statistics of gADC should be used with caution when ascribing significance to clinical changes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Treatment Response by Total Tumor Volume and Global Apparent Diffusion Coefficient Using Diffusion-Weighted MRI in Patients with Metastatic Bone Disease: A Feasibility Study

We describe our semi-automatic segmentation of whole-body diffusion-weighted MRI (WBDWI) using a Markov random field (MRF) model to derive tumor total diffusion volume (tDV) and associated global apparent diffusion coefficient (gADC); and demonstrate the feasibility of using these indices for assessing tumor burden and response to treatment in patients with bone metastases. WBDWI was performed ...

متن کامل

A Novel Whole Body Diffusion Weighted Imaging Technique with Continuously Moving Table: Preliminary Results

INTRODUCTION Influenced by the successful application of DWI to intracranial diseases, application of multistation DWI to whole-body has been proposed and used clinically for extracranial diseases [1]. However, the clinical impact of wbDWI remains limited due to technical difficulties which are inherent characteristics of multistation approach. As the continuously moving table (CMT) approach ha...

متن کامل

Diffusion Weighted Magnetic Resonance Imaging of metastatic bone disease: A biomarker for treatment response monitoring.

Diffusion Weighted Magnetic Resonance Imaging (DW-MRI) combined with conventional MRI can provide a whole body assessment of metastatic bone disease, improved lesion detection compared to other imaging techniques and a direct quantitative assessment of treatment response. In bone marrow, the presence of fat and bone trabeculae and their changing contributions with disease progression and respon...

متن کامل

Thallium - 201 imaging in osseous metastatic disease secondary to glioblastoma multiform

Thallium 201 whole body scintigraphy was performed in a 30 year old patient with diffuse osseous metastatic disease secondary to glioblastoma multiforme. Multiple sites of Thallium uptake correlated with the findings on serial bone scans and radiographs. Bone biopsy of a lower lumbar vertebra confirmed that the metastases were of glial origin.

متن کامل

A multicentre study on the reliability of qualitative and quantitative nail-fold videocapillaroscopy assessment.

OBJECTIVE To investigate the inter- and intra-observer reliability of both qualitative and quantitative parameters used in the assessment of nail-fold capillaroscopy images. METHODS Fifty mosaic nail-fold images of healthy controls (n = 10), patients with primary RP (n = 10) and SSc (n = 30) were assessed in random order by two blinded observers on two occasions at centres in Sweden, UK and T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016