Nephelometric determination of carbohydrate deficient transferrin.

نویسندگان

  • F Schellenberg
  • M Martin
  • E Cacès
  • J Y Bénard
  • J Weill
چکیده

We describe a technique for measuring carbohydrate-deficient transferrin (CDT) in serum. Serum transferrin fractions are separated by anion-exchange chromatography on microcolumns. Sialic acid-deficient transferrin fractions are collected in the eluate, and transferrin is then quantified by a rate-nephelometric technique. Imprecision (CV) was 4-5% within-run and 7-9% between runs (n = 15). Comparison with an isoelectric focusing-immunofixation method for transferrin index (x) yielded y = 761x + 7, Sy/x = 39 mg/L. Assay of sera from 90 abstainers or moderate consumers of alcohol showed that 81 (90%) had CDT concentrations between 30 and 70 mg/L. Among 74 alcoholics admitted to an alcohol treatment center, 54 (73%) had CDT > 70 mg/L, i.e., the diagnostic sensitivity was 73% at a specificity of 90% (area under receiver-operator characteristic curve = 0.891).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Genetic variation in the MTHFR gene influences thiopurine methyltransferase activity.

carbohydrate-deficient glycoprotein syndrome. Electrophoresis 1997;18: 1819–26. 12. Tagliaro F, Crivellente F, Manetto G, Puppi I, Deyl Z, Marigo M. Optimised determination of carbohydrate deficient transferrin isoforms (CDT) in serum by capillary zone electrophoresis. Electrophoresis 1998;19:3033–9. 13. Crivellente F, Fracasso G, Valentini R, Manetto G, Riviera AP, Tagliaro F. Improved method ...

متن کامل

Validation by isoelectric focusing of the anion-exchange isotransferrin fractionation step involved in determination of carbohydrate-deficient transferrin by the CDTect assay.

Serum concentration of carbohydrate-deficient transferrin (CDT) is used for laboratory diagnosis of chronic alcohol abuse. Using isoelectric focusing for validation of the initial isotransferrin fractionation step involved in the determination of CDT by the CDTect assay, we found a complete in vitro iron saturation of transferrin and sufficient stability of the transferrin iron load during colu...

متن کامل

Quantification of carbohydrate-deficient transferrin by ion-exchange chromatography with an enzymatically prepared calibrator.

The current HPLC method for the determination of carbohydrate-deficient transferrin (CDT) yields ratios of CDT isoforms in relation to total transferrin, whereas the use of absolute concentrations obtainable in routine analysis by RIA and the reference ranges based here-upon is more convenient. We describe a modified HPLC method that likewise gives absolute CDT concentrations by using a calibra...

متن کامل

Carbohydrate-deficient transferrin measured by high-performance liquid chromatography and CDTect immunoassay.

Carbohydrate-deficient transferrin (CDT) was measured in three populations using anion-exchange chromatography followed by radioimmunoassay (CDTectTM) and a new high-performance liquid chromatography (HPLC) method. The correlation between the methods in 50 consecutive clinical samples was good (r = 0.87). However, in a set of 49 samples with CDT concentrations close to the reference value of th...

متن کامل

Investigation by isoelectric focusing of the initial carbohydrate-deficient transferrin (CDT) and non-CDT transferrin isoform fractionation step involved in determination of CDT by the ChronAlcoI.D. assay.

BACKGROUND The introduction of a new set of reagents for the determination of carbohydrate-deficient transferrin (CDT) as a marker of chronic alcohol abuse requires an independent evaluation of the analytic specificity of the test. This information is needed for correct interpretation and classification of test results. METHODS Isoelectric focusing on the PhastSystem(TM) followed by immunofix...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 1996