BACKGROUND The aim of this study was to investigate and compare the clinical efficacy of modular cementless stem and coated cementless long-stem prostheses in hip revision arthroplasty. MATERIAL AND METHODS Sixty-five patients with complete hip revision surgery data during January 2005 to March 2015 were selected from the People's Hospital of Linyi City and randomly divided into a S-ROM group (implanted with cementless modular stem prostheses, n=32) and a SLR-PLUS group (implanted with cementless coated long-stem prostheses, n=33). Harris score was used to evaluate the hip function of the patients in order to measure the clinical efficacy of the prostheses in total hip arthroplasty. Anteroposterior pelvic radiographs and lateral pelvic radiographs were taken and each patient's hip arthroplasty condition was recorded. Kaplan-Meier method was applied to compare the cumulative 5-year non-revision rate between the 2 prostheses and log-rank method was used to inspect the statistical data. RESULTS The Harris scores of both the S-ROM group and the SLR-PLUS group were significantly higher at 12 months after the operation than those before the operation (both P<0.05). The Harris scores of the patients with type I/II bone defects in the S-ROM group were not significantly different from those of the same types in the SLR-PLUS group at all time points (all P>0.05), while the Harris scores of the patients with type IIIA/IIIB in the S-ROM group were both significantly higher than those of the same types in the SLR-PLUS group at 3 months, 6 months, and 12 months after the operation (all P<0.05). No significant difference was found in the cumulative 5-year non-revision rate between the type I/II patients in the S-ROM group (92.31%) and the patients of the same types in the SLR-PLUS group (85.71%) (P>0.05). However, the cumulative 5-year non-revision rate of the type IIIA/IIIB patients in the S-ROM group (89.47%) was significantly different from the patients of the same types in the SLR-PLUS group (42.11%) (P<0.05). CONCLUSIONS The modular stem prostheses in hip revision arthroplasty were clinically more effective in the treatment of type IIIA and IIIB bone defects than the coated long-stem prostheses according to the Harris score and the cumulative 5-year non-revision rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Medium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty

There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significa...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

Outcomes of Dual Modular Cementless Femoral Stems in Revision Hip Arthroplasty

With an increasing number of primary hip replacements being performed every year, the burden of revision hip arthroplasty, for septic and aseptic loosening, recurrent dislocation or periprosthetic fracture, is also increasing. In recent years, different approaches to revising the femoral prosthesis have emerged; including both cemented and cementless techniques. With a stable cement mantle and ...

متن کامل

Total Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry

Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...

متن کامل

Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population

Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2016