A Novel Crowbar Protection Technique for DFIG Wind Farm during Fault Ride Through

نویسنده

  • Omar Noureldeen
چکیده

This paper proposes a terminal crowbar protection technique for Doubly Fed Induction Generators (DFIG) to protect the rotor converter and enhance network stability during grid disturbances. Simulation test using MATLAB-Simulink toolbox is implemented on a 9 MW wind farm exports its power to 120 KV grid. The simulation is performed using different values of crowbar resistances. The variations of rotor current, rotor speed, DC-link voltage, active power and reactive power of the wind farm are investigated. Also, a comparison between the conventional crowbar and the proposed crowbar protection techniques is investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Ride through Capability Improvement of Wind Turbine Based DFIG Considering an Optimized Crowbar Along with STATCOM under Grid Fault Condition

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

متن کامل

Fault Behavior of Wind Turbines

Synchronous generators have always been the dominant generation type in the grid. This fact affected both planning and operation of power systems. With the fast increase of wind power share in the grid in the last decade, the situation is changing. In some countries wind power represents already a consistent amount of the total generation. Wind turbines can be classified as non-synchronous gene...

متن کامل

Analyzing the Application of Crowbar And Statcom To Overcome Voltage Sags With Actual Field Data

Wind power generation is increasing rapidly in India and wind integration with the grid is considered as a promising source of energy, Double Fed Induction Generator (DFIG) being the most commonly used wind turbine generator, when integrated with the grid show challenges during grid faults. This paper focuses on the challenges faced by DFIG during the occurrence of voltage sags and the Low Volt...

متن کامل

Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit

Doubly Fed Induction Generators DFIG are nowadays widely used in variable speed wind power plants. The dynamic interaction between variable speed DFIG wind turbines and the power system which is subjected to disturbances, such as short circuit faults, is an important issue. The ability of the wind power plant to stay connected to the grid during disturbances is important to avoid a cascading ef...

متن کامل

Differential Evolution Based IDWNN Controller for Fault Ride-Through of Grid-Connected Doubly Fed Induction Wind Generators

The key objective of wind turbine development is to ensure that output power is continuously increased. It is authenticated that wind turbines (WTs) supply the necessary reactive power to the grid at the time of fault and after fault to aid the flowing grid voltage. At this juncture, this paper introduces a novel heuristic based controller module employing differential evolution and neural netw...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012