Left ventricular ejection and filling rate measurement based on the automatic edge detection method of ECG-gated blood pool single-photon emission tomography.

نویسندگان

  • Takahiro Higuchi
  • Junichi Taki
  • Kenichi Nakajima
  • Seigo Kinuya
  • Masatoshi Ikeda
  • Masanobu Namura
  • Norihisa Tonami
چکیده

UNLABELLED The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data. METHODS Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera. From the left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG-gating during the equilibrium state. SPET GBP was conducted utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees by 60 sec per view, in 16 frames/cardiac cycle. In each frame, left ventricular volume was determined by automatic edge detection employing a quantitative gated SPET program. Additionally, the time-volume curve was fitted by the 4th harmonics of Fourier transform. Ejection fraction (EF, %), peak ejection rate (PER, /sec), peak filling rate (PFR, /sec) and mean filling rate during the initial one-third of diastolic time (1/3 FRm) were calculated from the fitted curve. These parameters were also calculated with planar GBP data. RESULT Left ventricular ejection and filling parameters were calculated by SPET GBP with the automatic edge detection program for all patient data. Correlation coefficients of EF, PER, PFR and 1/3 FRm between SPET and planar GBP were 0.91 (p < 0.001), 0.82 (p < 0.001), 0.78 (p < 0.001) and 0.74 (p < 0.001), respectively. CONCLUSION Ejection and filling rates can be calculated using SPET GBP with the edge-detection software. These parameters displayed significant correlations with those values obtained via planar GBP. Additional studies are warranted to determine the reliability of parameters with SPET GBP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Left ventricular volume and ejection fraction determined by gated blood pool emission tomography.

Electrocardiogram gated single photon emission computed tomography of the intracardiac blood pools is a recent development that involves the acquisition of images in multiple projections after in vivo erythrocyte labelling with technetium-99m and reconstruction of these images into tomographic sections in any desired plane. The technique was used in 25 subjects to measure left ventricular volum...

متن کامل

Comparison of left ventricular ejection fraction values obtained using invasive contrast left ventriculography, two-dimensional echocardiography, and gated single-photon emission computed tomography

OBJECTIVES Left ventricular ejection fraction can be measured by a variety of invasive and non-invasive cardiac techniques. This study assesses the relation of three diagnostic modalities to each other in the measurement of left ventricular ejection fraction: invasive contrast left ventriculography, two-dimensional echocardiography, and quantitative gated single-photon emission computed tomogra...

متن کامل

Left Ventricular Ejection Fraction: a Retrospective Study Comparing 2d Echocardiography and Gated Single Photon Emission Computed Tomography (spect) in Clinical Use

Objectives The aim of this study was to compare left ventricular ejection fraction (LVEF) results derived from gated single photon emission computed tomography (SPECT) using Cedars-Sinai quantitative gated SPECT (QGS) processing software with results from 2D echocardiography, both obtained in routine clinical diagnostic use. Methods Data from previously performed tests were obtained from 73 pat...

متن کامل

Detection of a biphasic response of hibernating myocardium by dobutamine-stress electrocardiography-gated technetium-99m-tetrofosmin single photon emission computed tomography--a case report.

A woman with coronary artery disease underwent a new imaging technique: dobutamine-stress electrocardiography (ECG)-gated tetrofosmin-single photon emission computed tomography (SPECT). Dobutamine-stress ECG-gated tetrofosmin-SPECT with automatic left ventricular function analysis software programs detected improvement and a biphasic response of dysfunctional myocardium during dobutamine infusi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2004