Intensity modulated radiotherapy: advantages, limitations and future developments
نویسنده
چکیده
Intensity modulated radiotherapy (IMRT) is widely used in clinical applications in developed countries, for the treatment of malignant and non-malignant diseases. This technique uses multiple radiation beams of non-uniform intensities. The beams are modulated to the required intensity maps for delivering highly conformal doses of radiation to the treatment targets, while sparing the adjacent normal tissue structures. This treatment technique has superior dosimetric advantages over 2-dimensional (2D) and conventional 3-dimensional conformal radiotherapy (3DCRT) treatments. It can potentially benefit the patient in three ways. First, by improving conformity with target dose it can reduce the probability of in-field recurrence. Second, by reducing irradiation of normal tissue it can minimise the degree of morbidity associated with treatment. Third, by facilitating escalation of dose it can improve local control. Early clinical results are promising, particularly in the treatment of nasopharyngeal carcinoma (NPC). However, as the IMRT is a sophisticated treatment involving high conformity and high precision, it has specific requirements. Therefore, tight tolerance levels for random and systematic errors, compared with conventional 2D and 3D treatments, must be applied in all treatment and pre-treatment procedures. For this reason, a large-scale routine clinical implementation of the treatment modality demands major resources and, in some cases, is impractical. This paper will provide an overview of the potential advantages of the IMRT, methods of treatment delivery, and equipment currently available for facilitating the treatment modality. It will also discuss the limitations of the equipment and the ongoing development work to improve the efficiency of the equipment and the treatment techniques and procedures.
منابع مشابه
3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملThe evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy
Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...
متن کاملIntensity-modulated radiotherapy—what is it?
Intensity-modulated radiotherapy (IMRT) is one of the most important recent developments in oncology. It enables precise conformation of the radiation dose to the target volume. It has the potential to significantly reduce long-term morbidity and improve local control. This article explains the basic principles of IMRT in comparison to other planning techniques. The current clinical data are pr...
متن کاملInfluence of Compensator Thickness and Field Size on Buildup factor of a Brass Compensator for Intensity- Modulated Radiation Therapy
Introduction: Radiotherapy is one of the effective methods in the treatment of cancer. In the recent methods of radiotherapy, intensity modulated radiotherapy (IMRT) technique by compensators is used. when photon beam passes the compensator, scattered photons can be generated within the compensator. The presence of scattered photons may complicate the design of compensators as...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2 شماره
صفحات -
تاریخ انتشار 2006