Doppler echocardiographic assessment of TTK Chitra prosthetic heart valve in the mitral position.

نویسندگان

  • Narayanan Namboodiri
  • Othayoth Shajeem
  • Jaganmohan A Tharakan
  • R Sankarkumar
  • Thomas Titus
  • Ajitkumar Valaparambil
  • Sivasubramonian Sivasankaran
  • Kavassery Mahadevan Krishnamoorthy
  • Sivadasan Pillai Harikrishnan
  • Santosh Kumar Dora
چکیده

AIMS TTK Chitra heart valve prosthesis (CHVP), a tilting disc mechanical heart valve of low cost and proven efficacy, has been in use for the last 15 years. Although various studies substantiating its long-term safety and efficacy are available, no study had assessed its echocardiographic characteristics. The purpose of this study was to determine the normal Doppler parameters of CHVP in the mitral position and to assess whether derivation of mitral valve area (MVA) using the continuity equation (CE) and more commonly used pressure half-time (PHT) method is comparable in the functional assessment of this tilting disc mitral prosthesis. METHODS AND RESULTS Doppler echocardiography was performed in 40 consecutive patients with CHVP in the mitral position. All patients were clinically stable, without evidence of prosthetic valve dysfunction such as significant obstruction or regurgitation, endocarditis, left ventricular dysfunction (ejection fraction <40%), or significant aortic regurgitation. Valve sizes studied included 25, 27, and 29 mm. Mitral valve area was derived both by the PHT method and by the CE, using the stroke volume measured in the ventricular outflow tract divided by the time-velocity integral of CHVP jet. The peak Doppler gradient ranged from 5 to 21 (mean 11.0) mmHg, and the mean gradient ranged from 1.7 to 9.2 (mean 4.1) mmHg. Mean gradient negatively correlated with an increase in the actual orifice area (AOA) derived from the valve orifice diameter given by the manufacturer (r = -0.45, P = 0.004). Mitral valve area calculated by both PHT and CE increased significantly with an increase in the AOA (r = 0.42, P = 0.007 and r = 0.32, P = 0.046, respectively). Mitral valve area by the CE averaged 1.55 +/- 0.36 cm(2) (range 0.85 cm(2) for a 25 mm valve to 2.41 cm(2) for a 29 mm valve) and was smaller than by PHT (mean 2.04 +/- 0.41 cm(2), range 1.40-3.14 cm(2); P = 0.0001; t-test), irrespective of whether PHT is less than or >110 ms. CONCLUSION The Doppler parameters obtained with CHVP in the mitral position are comparable with those obtained with the different prosthetic valves in common use. In the selected group of patients with CHVP, assessment of MVA by the PHT method is comparable with that by the CE. Areas by both methods were smaller than the AOA provided by the manufacturer, as seen in other similar design valves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic Profile of Normaly Functioning TTK Chitra Tilting Disc Prosthetic Valves

Background and aim of the study: TTK Chitra is a tilting disc prosthetic cardiac valve being used in India. We present the echocardiographic and Doppler evaluation of normally functioning valve in mitral and aortic positions. Methods: A total of 120 patients with 134 valves implanted in the aortic and/or mitral position were studied. All patients underwent a detailed echocardiographic and Doppl...

متن کامل

Transcranial Doppler application for risk assessment of stroke in patients with mechanical mitral valve

Introduction: Observing microembolic signals in brain vessels by transcranial Doppler technology is a very common finding in patients with mechanical heart valve. These signals are almost always clinically asymptomatic. The aim of this study was assessment of transcranial Doppler in detecting probability of stroke in patients with mechanical heart valve. Methods: This descriptive study was ca...

متن کامل

Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping.

We studied the value of two-dimensional Doppler echocardiographic color flow mapping for identifying normal transvalve flow profiles and valve malfunction in 20 patients with Björk-Shiley prosthetic valves. Seven patients had Björk-Shiley prosthetic valves in the aortic position alone, seven in the mitral position, and six had prosthetic valves in both the aortic and mitral positions. In 10 pat...

متن کامل

Doppler echocardiographic characteristics of normal and dysfunctioning prosthetic valves in the tricuspid and mitral position.

The Doppler echocardiographic characteristics of 70 prosthetic valves in 35 patients are reported. Twenty nine patients had a Björk-Shiley prosthesis in both mitral and tricuspid positions and six had Carpentier-Edwards valves in both sites. Five of the patients had abnormal tricuspid prostheses on the basis of clinical and echocardiographic criteria. Pulsed wave Doppler echocardiography was us...

متن کامل

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 12 10  شماره 

صفحات  -

تاریخ انتشار 2008