Quality of the threshold algorithm in age-related macular degeneration: Stratus versus Cirrus OCT.

نویسندگان

  • Ilse Krebs
  • Christiane Falkner-Radler
  • Stefan Hagen
  • Paulina Haas
  • Werner Brannath
  • Shilla Lie
  • Siamak Ansari-Shahrezaei
  • Susanne Binder
چکیده

PURPOSE Automatically generated measurements of the retinal volume or the central retinal thickness are based on correctly set threshold lines on the retinal surface and the retinal pigment epithelium. The purpose of this study was to compare the accuracy of threshold algorithm lines of Stratus optical coherence tomography (OCT) with those of Cirrus OCT. METHODS A consecutive series of patients at least 50 years of age with exudative age-related macular degeneration was included. Stratus OCT (retinal thickness program) and Cirrus OCT (macular cube 512 x 128) were performed by the same examiner, the sequence of the examinations was randomized. Two independent examiners evaluated the positioning of the threshold algorithm lines and performed a grading of the failures. Logistic regression analysis was applied for evaluation of the failure rate. RESULTS One hundred four patients were included. For the entire OCT examination (6 scans Stratus OCT, 128 scans Cirrus OCT) algorithm line failures were detected in 69.2% of the Stratus OCT and in 25% of the Cirrus OCT examinations, with the difference reaching statistical significance (P < 0.001). The median failure grade was 1 (0-6) for Stratus and 0 (0-5.15) for Cirrus OCT. Age, measurement sequence, and investigator did not influence the error rates. CONCLUSIONS With Cirrus OCT automatically performed and therefore objective measurements of central retinal thickness and retinal volume were provided correctly in 69.2% of the scans. Furthermore, this latest software version offers the possibility of manual correction of false positioned algorithm lines (ClinicalTrials.gov number, NCT00568191).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and reproducibility of spectral and time domain optical coherence tomography images before and after correction for patients with age-related macular degeneration

PURPOSE To evaluate the reproducibility and reliability of Optical Coherence Tomography scans (OCT) obtained using the Time Domain (TD-OCT) StratusTM OCT, and the Spectral Domain (SD-OCT) SpectralisTM and CirrusTM OCT devices before and after manual correction in eyes with either Neovascular (NV-AMD) or Non-Neovascular (NNV-AMD) Age-related Macular Degeneration. METHODS We conducted a prospec...

متن کامل

Comparison of spectral-domain and time-domain optical coherence tomography in the detection of neovascular age-related macular degeneration activity.

PURPOSE To compare the sensitivity of commonly used time-domain (TD-OCT) and spectral-domain optical coherence tomography platforms and scanning modalities in the management of neovascular age-related macular degeneration in a population with a high prevalence of exudative disease activity. METHODS Fifty consecutive patients within the prospective SAVE (Super-dose Anti-Vascular Endothelial gr...

متن کامل

Macular thickness assessed with spectral domain OCT in a population-based study of children: normative data, repeatability and reproducibility and comparison with time domain OCT.

PURPOSE To collect data on macular thickness assessed with Cirrus OCT in healthy children in a population-based study, to examine the repeatability and reproducibility, and to compare the values with Stratus OCT. METHODS Fifty-eight 6- to 15-year-old children, born at term, were examined. Best-corrected visual acuity and refraction were assessed. One examiner performed three OCT assessments, ...

متن کامل

Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion

Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and retinal vein occlusion (VO). Methods. In a prospective observational study at a university-based...

متن کامل

Spectral domain OCT versus time domain OCT in the evaluation of macular features related to wet age-related macular degeneration

BACKGROUND The aim of this study was to compare the agreement between spectral domain optical coherence tomography (SD OCT) and time domain stratus OCT (TD OCT) in evaluating macular morphology alterations in wet age-related macular degeneration (AMD). METHODS This retrospective study was performed on 77 eyes of 77 patients with primary or recurring subfoveal choroidal neovascularization seco...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2009