Validation of screening examinations of the ureteral orifices in dogs: Comparison of ultrasonography with dissection.

نویسندگان

  • O Balogh
  • F Degrandi
  • M Hässig
  • I M Reichler
چکیده

In dogs, ultrasonography is performed to locate the ureteral orifices in the urinary bladder, but reference values for their normal location using this technique are missing. In this study, the ureterovesical-vesicourethral and inter-ureterovesical distances were determined in 20 freshly euthanized medium size dogs by detecting artificially produced ureteral jets in color-flow Doppler ultrasonography at two different bladder volumes, and comparing them to manual measurements in the dissected bladder. All distances determined by ultrasonography were in agreement with values found by dissection (P ≥ 0.100). With increasing bladder volume only the left ureterovesical-vesicourethral distance changed (P = 0.041). The right ureteral opening was more cranial than the left in 16 dogs. The inter-ureterovesical distances differed by gender (P = 0.016), but spay/neuter status had no influence (P ≥ 0.847). In conclusion, ultrasonography is a reliable modality for screening ureteral orifices in medium size dogs and agrees with anatomical findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ultrasonography in Diagnosis of Nasal Fracture and Compared it with Plain Radiography in Dogs

Objective- One of the important causes of nasal fracture is a trauma that can be diagnosed in clinical examinations and diagnostic imaging but it should be noted that radiography may show false fractures in the nose. This study evaluates the value of ultrasonography in the diagnosis of nasal fractures and compared it with plain radiography. Design- Retrospective study. Animals- 12 d...

متن کامل

Evaluation of the ureteral jet in dogs by using color Doppler ultrasonography

Ureteral jets are the result of a forceful ejection of urine from the vesicoureteral junction into the urinary bladder. By using color Doppler ultrasonography (US), we aimed to identify distinct ureteral jets in dogs, provide insight into ureteral obstruction, and facilitate study of urodynamics and vesicoureteric sphincter function via pulsed Doppler US. Color Doppler US was applied to detect ...

متن کامل

Comparison of Transabdominal and Transrectal Ultrasonography of the Prostate Gland in Dogs

Objective- To compare transabdominal (TA) and transrectal (TR) ultrasonography of the prostate gland. Design- Experimental study. Animals- 10 intact male dogs that required euthanasia for reasons other than prostatic disease. Procedures- Prostatic length (L), width (W) and height (H) were measured in T A (L1, W1 and H1) and TR (L2 and H2...

متن کامل

Comparison of Transcorneal and Transpalpebral Ultrasonographic Measurements of the Eye in Iranian Mix Breed Dog

Objective-The aim of this research was to compare transcorneal and transpalpebral ultrasonography study of the dimensions (ecobiometry) and the ultrasonographic aspect of Iranian mix breed dogs.Design- Experimental studyAnimals- . Ten adult male dogsProcedure- Ten adult male dogs with the mean age 4±1.39 years...

متن کامل

Ultrasonographic Volumetry of the Canine Thyroid Gland: A Comparison of 2D, 3D Ultrasonography and Real Gland Volume

Objective: to compare the estimated thyroid volume, as determined by two-dimensional (2D) and three-dimensional (3D) ultrasonography, with real volume. Design: Descriptive Study Animals: A total of 7 mixed breed dogs Procedures: On 2D ultrasound, the thyroid volume is estimated by the ellipsoid equation and on 3D ultrasound; it is estimated by outlining the boundaries of the thyroid lobe in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Research in veterinary science

دوره 101  شماره 

صفحات  -

تاریخ انتشار 2015