Accuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK
نویسندگان
چکیده
PURPOSE To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). MATERIALS AND METHODS This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a desired depth of 120 μm. Optical low-coherence reflectometry (WaveLight EX500) was used to measure central corneal thickness prior to lifting the flap, and the residual stromal bed immediately after excimer ablation. Flap thickness (FT) was calculated using simple subtraction. Optical coherence tomography (OCT) was used to measure central corneal thickness, flap thickness, and residual stromal bed in the postoperative period and the results compared to intraoperative measurements. RESULTS Mean programmed FS200 FT was 119 μm. Mean FT using EX500 optical pachymetry was 109 μm. The difference between FS200- programmed and EX500-measured FT was 9 μm (P<0.001). There was also a significant difference between the EX500 and OCT FT (109 μm vs 119 μm, respectively; P<0.001). CONCLUSION FT values calculated using intraoperative EX500 optical pachymetry were significantly lower than programmed FS200 values or OCT measurements.
منابع مشابه
Predictability of Corneal Flap Thickness in LASIK Using the WaveLight FS200 Femtosecond Laser
250 of 250 words) Purpose: To compare the intended versus resultant thickness of laser in situ keratomileusis (LASIK) flaps created with a new femtosecond laser (WaveLight FS200 Femtosecond Laser, WaveLight GmbH, Alcon Laboratories) and to report refractive outcomes at 3 months posttreatment. Setting: Wellington Eye Clinic, Dublin, Ireland Design: Retrospective consecutive case series Methods: ...
متن کاملComparison of corneal flap thickness using a FS200 femtosecond laser and a moria SBK microkeratome.
AIM To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a 110-µm-thick corneal flap and to identify the potential factors that affect corneal flap thickness. METHODS A prospective case study was performed on 120 eyes of 60 patients who were divided into two groups for LASIK, each group consisting ...
متن کاملLong-term safety and efficacy follow-up of prophylactic higher fluence collagen cross-linking in high myopic laser-assisted in situ keratomileusis
BACKGROUND The purpose of this study was to evaluate the safety and efficacy of ultraviolet A irradiation cross-linking on completion for cases of high myopic laser-assisted in situ keratomileusis (LASIK). METHODS Forty-three consecutive LASIK cases treated with femtosecond laser flap and the WaveLight excimer platform were evaluated perioperatively for uncorrected visual acuity, best correct...
متن کاملTreatment of moderate-to-high hyperopia with the WaveLight Allegretto 400 and EX500 excimer laser systems
PURPOSE To evaluate the efficacy of treating patients with +3.00 diopters (D) to +6.00 D of hyperopia via laser-assisted in situ keratomileusis (LASIK) with the WaveLight Allegretto 400 and EX500 excimer laser systems. SETTING Private clinical ophthalmology practice. PATIENTS AND METHODS This was a retrospective study of patients undergoing LASIK treatments of +3.00 to +6.00 D on two differ...
متن کاملDigital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique
BACKGROUND The purpose of this study was to determine flap parameter accuracy, extent of the opaque bubble layer, and incidence of skip lines in femtosecond laser-assisted stromal in situ keratomileusis (LASIK) using the WaveLight(®) FS200 laser and optoelectronic clinical measurements. METHODS Images from 101 flaps were automatically recorded during consecutive routine LASIK procedures perfo...
متن کامل