Neural-Networks and Synchronous Reference Frame Applied in the Harmonic Compensation with a Three-Phase Parallel Active Power Filter
نویسندگان
چکیده
This paper presents an alternative method based on artificial neural network, which is used to obtain the reference currents for harmonic current suppression and reactive power compensation in a shunt active power filter applied to three-phase four-wire system. The neural network consists of a multilayer perceptron, which is trained to estimate the peak amplitude of the load fundamental component currents. The performance of the proposed artificial neural network is evaluated by computer simulation, and it is compared with the method based on synchronous reference frame.
منابع مشابه
Comparative Power Quality Analysis of Different DSTATCOM Topologies
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملActive Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملIndirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays
The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...
متن کاملHarmonic Elimination of 25 kV AC Electric Railways Utilizing a New Hybrid Filter Structure
Thyristor rectifiers are widely used in electric railways in order to control the speed. As a consequence of their usage in addition to substantial input lead current, an enormous amount of harmonics is injected into the grid. To avoid such harmonics as well as reactive power compensation, reactive power hybrid filters consisting of active and passive filters are utilized. Regarding different p...
متن کامل