Fretting and corrosion in modular-neck total hip arthroplasty femoral stems.

نویسندگان

  • Dennis O Molloy
  • Selin Munir
  • Christopher M Jack
  • Michael B Cross
  • William L Walter
  • William K Walter
چکیده

BACKGROUND During total hip arthroplasty, use of a modular femoral neck on a stemmed implant allows optimization of neck anteversion, length, and offset, resulting in more accurate balance. We performed a retrospective analysis of a consecutive cohort of patients who had undergone total hip arthroplasty with a modular-neck hip system with ceramic-on-ceramic bearings. METHODS We reviewed the results in fifteen patients who had received an ABG II dual modular hip system (Stryker Orthopaedics, Mahwah, New Jersey) from May 2007 to August 2008. Anteroposterior radiographs of the pelvis were reviewed and scored with regard to medial calcar erosion. Magnetic resonance imaging (MRI) was performed to assess for adverse local tissue reaction around the hip joint. Calcar resorption was correlated with subsequent MRI findings. Retrieval analysis was performed on the implants removed at revision. RESULTS The mean duration of follow-up for all patients was 42.3 months (range, thirty-three to sixty months). Cobalt-ion levels were elevated in all patients; chromium levels were within the normal range. Medial femoral calcar erosion was noted in seven of the fifteen cases. All patients with grade-2 or 3 calcar erosion on radiographs had positive MRI findings consistent with adverse local tissue reaction. At the time of writing, seven patients had undergone revision arthroplasty. Intraoperatively, tissue staining with tissue and bone necrosis and pseudotumor formation were observed in all revision cases. Histological analysis confirmed the presence of metal-on-metal synovitis, with changes similar to those seen with metal-on-metal bearings. CONCLUSIONS The ABG II dual modular hip system is associated with a high rate of early failure secondary to fretting and corrosion at the femoral neck-stem taper. The component has subsequently been recalled and is no longer in use. Surgeons using modular hip systems with a titanium stem and cobalt-chromium neck should be vigilant about annual follow-up with radiographs, and use of MRIs as indicated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fretting and Corrosion Damage at the Head-Neck Taper is Reduced with Ceramic Femoral Heads: A Retrieval Study

Introduction: Modular head-neck total hip arthroplasty (THA) offers several benefits for orthopaedic surgeons, including intraoperative flexibility and the ability to change the head at revision surgery [1]. However, modularity at the head-neck taper, especially the use of metallic heads and stems, can lead to fretting and corrosion at the taper junction, leading to metal ions and debris releas...

متن کامل

Fracture of Revision Modular Femoral Stem

The number of revision total hip arthroplasties is predicted to more than double in USA over the next 25 years from an estimated 40800 in 2005 to approximately 96700 in 2030 [1]. Modular femoral stems offer the advantage of adjustment and restoration of joint kinematics including leg length, femoral version and offset, regardless of the exact position of the distal part of the stem [2]. Disadva...

متن کامل

Do Ceramic Femoral Heads Reduce Taper Fretting Corrosion in Hip Arthroplasty? A Retrieval Study

BACKGROUND Previous studies regarding modular head-neck taper corrosion were largely based on cobalt chrome (CoCr) alloy femoral heads. Less is known about head-neck taper corrosion with ceramic femoral heads. QUESTIONS/PURPOSES We asked (1) whether ceramic heads resulted in less taper corrosion than CoCr heads; (2) what device and patient factors influence taper fretting corrosion; and (3) w...

متن کامل

Novel concept of a modular hip implant could contribute to less implant failure in THA: a hypothesis

Background The modularity in total hip arthroplasty (THA) allows orthopaedic surgeons for an exact reconstruction of hip biomechanical parameters especially in revision and tumor arthroplasty. Modular structured femoral stems using taper junctions showed increased implant breakage in the recent past. Presentation of the hypothesis We hypothesize that a novel modular stem-neck-interface leads ...

متن کامل

Modular titanium alloy neck failure in total hip replacement: analysis of a relapse case.

Modular neck hip prosthesis born in the 1990 with the aim of allowing the surgeon to modify CCD angle, offset and femoral anteversion intra-operatively restoring patient's original biomechanics. In order to achieve the best biomechanics of the reconstructed hip, preoperative planning is essential. In the last few years modularity has been questioned and an argument made for the return to mono b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 96 6  شماره 

صفحات  -

تاریخ انتشار 2014