Asthma pressurised metered dose inhaler performance: propellant effect studies in delivery systems

نویسنده

  • William F. S. Sellers
چکیده

BACKGROUND Current pressurised metered dose asthma inhaler (pMDI) propellants are not inert pharmacologically as were previous chlorofluorocarbons, have smooth muscle relaxant' partial pressure effects in the lungs and inhaled hydrofluoroalkane 134a (norflurane) has anaesthetic effects. Volumes of propellant gas per actuation have never been measured. METHODS In-vitro studies measured gas volumes produced by pMDIs on air oxygen (O2) levels in valved holding chambers (VHC) and the falls in O2% following actuation into lung ventilator delivery devices. RESULTS Volumes of propellant gas hydrofluoroalkane (HFA) 134a and 227ea and redundant chlorofluorocarbons (CFC) varied from 7 ml per actuation from a small salbutamol HFA inhaler to 16 ml from the larger. Similar-sized CFC pMDI volumes were 15.6 and 20.4 ml. Each HFA salbutamol inhaler has 220 full volume discharges; total volume of gas from a small 134a pMDI was 1640 ml, and large 3885 ml. Sensing the presence of liquid propellant by shaking was felt at the 220th discharge in both large and small inhalers. Because of a partial pressure effect, VHC O2% in air was reduced to 11% in the smallest 127 ml volume VHC following 10 actuations of a large 134a salbutamol inhaler. The four ventilator delivery devices studied lowered 100% oxygen levels to a range of 93 to 81% after five actuations, depending on the device and type of pMDI used. CONCLUSION Pressurised inhaler propellants require further study to assess smooth muscle relaxing properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Improvement of drug delivery with a breath actuated pressurised aerosol for patients with poor inhaler technique.

BACKGROUND The metered dose inhaler is difficult to use correctly, synchronising actuation with inhalation being the most important problem. A breath actuated pressurised inhaler, designed to help patients with poor inhaler technique, was compared with a conventional metered dose inhaler in terms of aerosol deposition and bronchodilator response. METHODS Radioaerosol deposition and bronchodilat...

متن کامل

Comparison of bronchodilator responses and deposition patterns of salbutamol inhaled from a pressurised metered dose inhaler, as a dry powder, and as a nebulised solution.

The lung dose and deposition patterns of drug delivered by dry powder inhaler are not known. The effects of inhaling 400 micrograms salbutamol delivered by dry powder inhaler (two 200 micrograms salbutamol Rotacaps), by pressurised metered dose inhaler, and by Acorn nebuliser were studied in nine subjects with chronic stable asthma. Technetium-99m labelled Teflon particles were mixed with micro...

متن کامل

New inhaler devices - the good, the bad and the ugly.

Drug delivery to the lungs is an effective way of targeting inhaled therapeutic aerosols and treating obstructive airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). In the past 10 years, several new drugs for the management of asthma and COPD have been marketed and more are under development. These new therapeutic respiratory drugs have been furthered by innovatio...

متن کامل

Pressurised metered dose inhalers with spacers versus nebulisers for beta-agonist delivery in acute asthma in children in the emergency department.

OBJECTIVES Wet nebulisers are widely used for beta-2 agonist delivery in Australasian emergency departments (ED). An increasing body of work suggests that pressurised metered dose inhalers with spacers (pMDI-S) are as effective. This study aims to investigate the effect on admission rates, total time in the ED, and total time in hospital after initiation of routine pMDI-S treatment for mild to ...