Radiation Protection in Interventional Radiology
نویسنده
چکیده
Interventional procedures are used by a significant number of medical specialities. Radiation protection (RP) for patients and staff is one of the main issues in Interventional Radiology (IR). UNSCEAR, ICRP and IAEA have devoted significant time over the last years to improve radiation safety in IR. Several combined factors: prolonged localized fluoroscopy, multiple radiographic exposures, and repeated procedures can cause acute radiation injury to the skin. The values of dose-area product and effective dose for IR are typically larger than those used in common diagnostic x-ray examinations. The studies carried out among the Chernobyl survivors show that cataracts may appear after doses of less than 1 Gy and these are the doses interventionists are likely to receive after several years' work. ICRP recommends taking into account occupational risks to justify IR procedures. The diagnostic reference levels can also be a useful tool to optimize IR procedures. In this paper, we present some of the ICRP practical recommendations concerning training in RP, patient dose records, clinical follow-up when skin doses are estimated too high, the use of personal dosimeters, etc. We also include the actions of other international and national organizations as well as scientific societies on radiation safety in IR. We also discuss the influence on IR of the new radiation risk and tissue weighting factors proposed by the ICRP in 2007. We finally give some results on patient dose surveys and staff dose estimations in IR and conclude with a list of challenging topics for the years to come.
منابع مشابه
Active electronic personal dosemeter in interventional radiology.
A recently developed active electronic personal dosemeter (AEPD) was utilised in order to measure the levels and the structure of occupational exposure to scattered X-ray radiation of medical staff who performed percutaneous revascularisation therapy that involves interventional radiology (IR) on the pelvis and upper leg arteries. The AEPDs, placed on the operators' and assistants' chests, that...
متن کاملRadiation dose and radiation protection for patients and physicians during interventional procedure.
Although the wide acceptance of interventional radiology (IVR) procedures has led to increasing numbers of interventions being performed, the radiation doses from IVR are higher. Increasing numbers of case reports of patient radiation injury resulting from IVR are being published. Therefore, radiation protection during IVR poses a very important problem. To protect against radiation injury, the...
متن کاملQuality improvement guidelines for recording patient radiation dose in the medical record for fluoroscopically guided procedures.
ACR American College of Radiology, CRCPD Conference of Radiation Control Program Directors, FDA Food and Drug Administration, ICRU International Commission on Radiation Units and Measurements, IEC International Electrotechnical Commission, IRP interventional reference point, Ka,r total air kerma at the interventional reference point, NCRP National Council on Radiation Protection and Measurement...
متن کاملEvaluation of radiation protection principles observance in radiology departments of Semnan University of medical sciences
Introduction: Most of people are exposed to ionizing radiation sources during their lifetime including background, cosmic or man-made beams like radiation used in nuclear medicine and radiology. Due to unavoidable use of ionizing radiation in diagnosis and treatment of diseases, designing and correct implementation of radiation protection principles in order to reducing its har...
متن کاملAssessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کامل