Investigation of Circuit Breaker Dielectric Performance

نویسنده

  • Xinming Zhang
چکیده

The violent event of a short-circuit leads to short-term exposure of circuit breaker components to extremely high current, causing thermal degradation, vaporization and deformation of some components and the deposition of surface contaminants. After short-circuit, the leakage current carried by the breaker, when voltage is applied, increases dramatically but must remain below a certain threshold to meet acceptance criteria. The goal of this study is to identify the primary leakage current pathways through the breaker following short-circuit and to elucidate the role of a protective coating, loaded with naturally-occurring clay nanoparticles, on improving the electrical performance of the breaker. A Megger insulation tester was used to test both virgin and short-circuited polycarbonate (PC) samples taken from the base of the circuit breaker. Further, direct-current and alternating-current conductivity were measured on PC samples by using a Keithley high-resistance meter and broadband dielectric spectroscopy, respectively. These tests established that the leakage current pathway is primarily through the surface contaminants deposited on the PC during the short-circuit event. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were employed to identify the composition and distribution of the surface contaminants. These were found to contain significant amounts of metal, accounting for the observed increase in leakage current through the breaker following short-circuit. The protective coating was studied by Fourier transform infrared spectroscopy, SEM and EDS, revealing the critical role played by insulating

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Electric Field and Polarization of SF6 Circuit Breaker to Approach a Suitable Structure

Abstract: The application of electric field theory to widely different aspects of electrical insulation has led to more understanding the phenomena. Electric fields may be considered as the main reason for insulation failure. The purpose of this paper is to modify importance of analyzing electric field in insulation design. The SF6 circuit breaker is chosen as case study that encounters cri...

متن کامل

SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress

In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...

متن کامل

Investigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment

Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...

متن کامل

Transient Recovery Voltage Investigation in the Application of 15 kV Circuit Breaker Failure

Circuit breakers can fail to interrupt fault current when the power system has transient recovery voltage (TRV) characteristics that exceed the rating of the circuit breaker. There were two incidents of failures of outdoor switchgear at a power plant substation. The cause of the failure for these breakers was investigated in order to determine if transient recovery voltage is a contributing fac...

متن کامل

An Innovative System for Full-Management of CB Using Current Injection Method

In this article, an innovative supervision system will be proposed that can observe and analyze health of Circuit Breaker’s trip coil. The proposed design also logs changes in the coil's quality and informs network supervisor in case of Circuit Breaker (CB) failure. This system injects small direct currents to the Circuit Breaker connections and the trip coil to compute CB’s health and characte...

متن کامل