Demonstration of high-precision continuous measurements of water vapor isotopologues in laboratory and remote field deployments using wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) technology.

نویسندگان

  • Priya Gupta
  • David Noone
  • Joseph Galewsky
  • Colm Sweeney
  • Bruce H Vaughn
چکیده

This study demonstrates the application of Wavelength-Scanned Cavity Ring-Down Spectroscopy (WS-CRDS) technology which is used to measure the stable isotopic composition of water. This isotopic water analyzer incorporates an evaporator system that allows liquid water as well as water vapor to be measured with high precision. The analyzer can measure H2(18)O, H2(16)O and HD(16)O content of the water sample simultaneously. The results of a laboratory test and two field trials with this analyzer are described. The results of these trials show that the isotopic water analyzer gives precise, accurate measurements with little or no instrument drift for the two most common isotopologues of water. In the laboratory the analyzer has a precision of 0.5 per mil for deltaD and 0.1 per mil for delta(18)O which is similar to the precision obtained by laboratory-based isotope ratio mass spectrometers. In the field, when measuring vapor samples, the analyzer has a precision of 1.0 per mil for deltaD and 0.2 per mil for delta(18)O. These results demonstrate that the isotopic water analyzer is a powerful tool that is appropriate for use in a wide range of applications and environments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field Testing of Cavity Ring-Down Spectroscopy Analyzers Measuring Carbon Dioxide and Water Vapor

Prevalent methods for making high-accuracy tower-based measurements of the CO2 mixing ratio, notably nondispersive infrared spectroscopy (NDIR), require frequent system calibration and sample drying. Wavelength-scanned cavity ring-down spectroscopy (WS-CRDS) is an emerging laser-based technique with the advantages of improved stability and concurrent water vapor measurements. Results are presen...

متن کامل

Applications of cavity ring-down spectroscopy to high precision isotope ratio measurement of 13C/12C in carbon dioxide.

Recent measurements of carbon isotopes in carbon dioxide using near-infrared, diode-laser-based cavity ring-down spectroscopy (CRDS) are presented. The CRDS system achieved good precision, often better than 0.2 per thousand, for 4% CO2 concentrations, and also achieved 0.15-0.25 per thousand precision in a 78 min measurement time with cryotrap-based pre-concentration of ambient CO2 concentratio...

متن کامل

ring-down spectroscopy with laser-current-tuned cavity resonance

High-precision analysis of the 17O / 16O isotope ratio in water and water vapor is of interest in hydrological, paleoclimate, and atmospheric science applications. Of specific interest is the parameter 17Oexcess (117O), a measure of the deviation from a linear relationship between 17O / 16O and 18O / 16O ratios. Conventional analyses of 117O of water are obtained by fluorination of H2O to O2 th...

متن کامل

Evanescent Wave Cavity Ring-down Spectroscopy: a Future Technology for Process Sensing

Evanescent wave cavity ring-down spectroscopy (EW-CRDS) is described. The total internal reflection (TIR)-ring and monolithic folded cavity designs are briefly discussed. The performance of EW-CRDS for trace water vapor detection is evaluated by accounting for surface chemical and physical properties as well as intrinsic resonator properties. INTRODUCTION Cavity ring-down spectroscopy (CRDS) us...

متن کامل

Quantitative Moisture Measurement with a Cavity Ring-down Spectrometer using Telecom Diode Lasers

Moisture measurement is of great needs in semiconductor industry, combustion diagnosis, meteorology, and atmospheric studies. We present an optical hygrometer based on cavity ring-down spectroscopy (CRDS). By using different absorption lines of H2O in the 1.56 and 1.36 μm regions, we are able to determine the relative concentration (mole fraction) of water vapor from a few percent down to the 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 23 16  شماره 

صفحات  -

تاریخ انتشار 2009