Bench study on active exhalation valve performance.

نویسندگان

  • Guang-Yu Jiao
  • John W Newhart
چکیده

BACKGROUND Ventilator exhalation-valve performance during the expiratory phase has been studied in depth. An active exhalation valve uses servo-control technology that allows gas to be released from the exhalation valve during the inspiratory phase if the patient makes an expiratory effort. We conducted a bench study of active exhalation valve response to expiratory effort during the inspiratory phase. METHODS We studied 4 ventilators that have active exhalation valves (Maquet Servo-i, Newport e500, Puritan Bennett 840, and Evita XL) and one that does not (Puritan Bennett 7200ae). With an active test lung we simulated various magnitudes of expiratory effort during the middle of the inspiratory phase. We measured the exhalation resistance and pressure over-shoot during the expiratory effort, and we measured the pressure under-shoot after the expiratory effort. The exhalation resistance of the 7200ae could not be determined because this ventilator did not allow any gas-release through the exhalation valve during the expiratory effort. RESULTS The exhalation resistance of the Evita XL (6.6 +/- 1.8 cm H(2)O/L/s) was higher than that of the Servo-i (3.0 +/- 1.3 cm H(2)O/L/s), e500 (2.6 +/- 0.8 cm H(2)O/L/s), and 840 (3.5 +/- 0.8 cm H(2)O/L/s) (all P < .001). The magnitude of pressure over-shoot during the expiratory efforts was not significantly different among the 4 ventilators with active exhalation valves. Pressure over-shoot was significantly higher with the 7200ae than with any of other ventilators (all P < .001). CONCLUSIONS There was a significant difference in exhalation resistance between the Evita XL and the other 3 ventilators with active exhalation valves. All 4 ventilators with active exhalation valves had lower exhalation resistance than the 7200ae.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Passenger Car Active Braking System: model and experimental validation (Part I)

The paper proposes a method to characterize the dynamic behavior of a normal production hydraulic brake system through experiments on a hardware-in-the-loop (HIL) test bench for both modeling (Part I) and control (Part II) tasks. The activity is relative to analyze, model and control ABS/ESC digital valves, aiming at obtaining reference tracking and disturbance-rejection performance similar to ...

متن کامل

Evaluation of exhalation valves.

Certification tests currently employed by some industrialized nations to certify respirators require that when challenged with air flow at a constant suction head of 25 mmH2O, the leakage into the facepiece from the exhalation valve(s) should not exceed 30 ml min(-1). However, the test alone might not reflect the leakage rate under different levels of vacuum. To study the characteristics of lea...

متن کامل

Physiological impact of the N95 filtering facepiece respirator on healthcare workers.

OBJECTIVE To assess the physiological impact of the N95 filtering facepiece respirator (FFR) on healthcare workers. METHODS Ten healthcare workers each conducted multiple 1-hour treadmill walking sessions, at 1.7 miles/h, and at 2.5 miles/h, while wearing FFR with exhalation valve, FFR without exhalation valve, and without FFR (control session). We monitored heart rate, respiratory rate, tida...

متن کامل

The Effects of Various Stimuli on Motivation and Physical Fitness of Physically Active and Non-Active Students

Background. Execution of fitness testing in physical education classes is influenced by students’ motivation. Therefore, addressing new testing approaches seems necessary to more accurately measure student performance. Objectives. This study presents changes in fitness performance after applying a physical fitness tests battery (without external stimuli - WS) and with external stimuli (verbal ...

متن کامل

Monitoring of noninvasive ventilation by built-in software of home bilevel ventilators: a bench study.

BACKGROUND Current bilevel positive-pressure ventilators for home noninvasive ventilation (NIV) provide physicians with software that records items important for patient monitoring, such as compliance, tidal volume (Vt), and leaks. However, to our knowledge, the validity of this information has not yet been independently assessed. METHODS Testing was done for seven home ventilators on a bench...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 53 12  شماره 

صفحات  -

تاریخ انتشار 2008