Quantification of Hepatic Iron Concentration in Chronic Viral Hepatitis: Usefulness of T2-weighted Single-Shot Spin-Echo Echo-Planar MR Imaging
نویسندگان
چکیده
OBJECTIVE To investigate the usefulness of single-shot spin-echo echo-planar imaging (SSEPI) sequence for quantifying mild degree of hepatic iron stores in patients with viral hepatitis. METHODS This retrospective study included 34 patients with chronic viral hepatitis/cirrhosis who had undergone histological investigation and magnetic resonance imaging with T2-weighted gradient-recalled echo sequence (T2-GRE) and diffusion-weighted SSEPI sequence with b-factors of 0 s/mm(2) (T2-EPI), 500 s/mm(2) (DW-EPI-500), and 1000 s/mm(2) (DW-EPI-1000). The correlation between the liver-to-muscle signal intensity ratio, which was generated by regions of interest placed in the liver and paraspinous muscles of each sequence image, and the hepatic iron concentration (µmol/g dry liver), which was assessed by spectrophotometry, was analyzed by linear regression using a spline model. Akaike information criterion (AIC) was used to select the optimal model. RESULTS Mean ± standard deviation of the hepatic iron concentration quantified by spectrophotometry was 24.6 ± 16.4 (range, 5.5 to 83.2) µmol/g dry liver. DW-EPI correlated more closely with hepatic iron concentration than T2-GRE (R square values: 0.75 for T2-EPI, 0.69 for DW-EPI-500, 0.62 for DW-EPI-1000, and 0.61 for T2-GRE, respectively, all P<0.0001). Using the AIC, the regression model for T2-EPI generated by spline model was optimal because of lowest cross validation error. CONCLUSION T2-EPI was sensitive to hepatic iron, and might be a more useful sequence for quantifying mild degree of hepatic iron stores in patients with chronic viral hepatitis.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملHepatic Iron Deposition in Liver Disease -- Which Method Works Best? Quantification of Hepatic Iron Deposition in Patients With Liver Disease: Comparison of Chemical Shift Imaging With Single-Echo T2*-Weighted Imaging
Objective: To determine if chemical shift imaging is comparable to single-echo T2*-weighted imaging in the quantification of hepatic iron, and if coexisting steatosis affects its performance. Design: Retrospective analysis. Participants/Methods: This study was comprised of 63 patients (50 men and 13 women) who had undergone MRI of the liver and concomitant histopathologic analysis within 90 day...
متن کاملDetection of focal hepatic lesions with MR imaging: prospective comparison of T2-weighted fast spin-echo with and without fat suppression, T2-weighted breath-hold fast spin-echo, and gadolinium chelate-enhanced 3D gradient-recalled imaging.
OBJECTIVE The purpose of this study was to compare breath-hold three-dimensional (3D) rapid gradient-echo (GRE) MR imaging obtained before and after gadolinium chelate injection with T2-weighted fast spin-echo and T2-weighted breath-hold fast spin-echo (BHFSE) MR imaging in the detection of focal hepatic masses. SUBJECTS AND METHODS Fifty-three patients with 108 focal hepatic masses had, pros...
متن کاملSingle-shot, turbo spin-echo, diffusion-weighted imaging versus spin-echo-planar, diffusion-weighted imaging in the detection of acquired middle ear cholesteatoma.
Diagnosis of acquired middle ear cholesteatoma on MR imaging is mostly done on late postgadolinium T1-weighted MR images and/or echo-planar (EPI) diffusion-weighted (DWI) MR images. We describe the appearance of a case of a complicated attical middle ear cholesteatoma on single-shot (SS) turbo spin-echo (TSE) DWI compared with EPI-DWI. This case suggests a higher reliability of SS TSE-DWI in th...
متن کاملIron-induced susceptibility effect at the globus pallidus causes underestimation of flow and volume on dynamic susceptibility contrast-enhanced MR perfusion images.
BACKGROUND AND PURPOSE Age-related iron accumulation in extrapyramidal nuclei causes T2 shortening, which may result in decreased signal intensity in these areas on MR images. Because the dynamic susceptibility contrast-enhanced technique uses heavily T2*- or T2-weighted images, the iron-induced susceptibility may have direct impact on perfusion imaging. The purpose of this study was to assess ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2012