Corneal biomechanical changes after collagen cross-linking from porcine eye inflation experiments.
نویسندگان
چکیده
PURPOSE Understanding corneal biomechanics is important to refractive or therapeutic corneal treatments. The authors studied the corneal response to variable intraocular pressure (IOP) in porcines eyes after UV collagen cross-linking (CXL), in comparison with untreated eyes. METHODS Twenty-three enucleated eyes were treated with standard CXL conditions (365 nm, 3 mW, 30 minutes), and 15 contralateral eyes served as control. Eyes (within a humidity- and temperature-monitored wet chamber) were measured by Scheimpflug corneal three-dimensional topographer. Images were obtained automatically while IOP either remained constant (14 eyes) or increased (24 eyes) by 40 mm Hg and then decreased (4-mm Hg steps). Measurements were performed immediately after treatment and 24 hours later. Corneal geometry was analyzed as a function of IOP, and whole globe stress-strain curves were calculated. RESULTS Instillation of riboflavin-dextran solution reduced corneal thickness (by 281 +/- 5 microm). Cross-linking produced a 1.54x reduction in corneal thinning and 2.8x reduction in corneal apical rise with increased IOP. Anterior and posterior cornea flattened with increased IOP (less flattening in CXL eyes) and became steeper with decreased IOP. The horizontal meridian flattened significantly (P < 0.01) more than the vertical meridian. Young's modulus was higher in cross-linked eyes (1.096 +/- 0.30 kN/m(2)) than in non-cross-linked eyes (0.692 +/- 0.30 kN/m(2)). Hysteresis in nontreated eyes was also larger than in cross-linked eyes. CONCLUSIONS Cross-linking stiffened porcine corneas significantly. Both experimental data and stress-strain analysis are valuable for finite element models to improve understanding of CXL and its predictability. Although differences are expected between human corneas in vivo and porcine corneas ex vivo, the results are consistent with clinical data found in patients. The apparent biomechanical anisotropy of pig corneas must be confirmed in humans.
منابع مشابه
Biomechanical Changes After LASIK Flap Creation Combined With Rapid Cross-Linking Measured With Brillouin Microscopy.
PURPOSE To evaluate the biomechanical changes occurring after LASIK flap creation and rapid corneal cross-linking (CXL) measured with Brillouin light microscopy. METHODS Porcine eyes (n = 11) were evaluated by Brillouin light microscopy sequentially in the following order: virgin state, after LASIK flap creation, and after rapid CXL. Each eye served as its own control. Depth profile of the Br...
متن کاملPhotochemical activation increases the porcine corneal stiffness and resistance to collagenase digestion.
In this study, we explore the effect of photochemical activation induced corneal cross-linking, utilizing Rose Bengal (RB) and 532 nm green light irradiation (RB-PCL), on porcine corneal biomechanical rigidity and the biochemical resistance against collagenase digestion. A protocol with a wavelength of 532 nm and illumination intensity of 0.4W/cm(2) for 250 s to deliver a dose of 100 J/cm(2) wa...
متن کاملA Constant-Force Technique to Measure Corneal Biomechanical Changes after Collagen Cross-Linking
PURPOSE To introduce a constant-force technique for the analysis of corneal biomechanical changes induced after collagen cross-linking (CXL) that is better adapted to the natural loading in the eye than previous methods. METHODS For the biomechanical testing, a total of 50 freshly enucleated eyes were obtained and subdivided in groups of 5 eyes each. A Zwicki-Line Testing Machine was used to ...
متن کاملCross-Linking of Corneal Collagen with UVA and Riboflavin for the Treatment of Corneal Disease
Introduction In recent years, reduced corneal biomechanics have been identified as an important element in the pathogenesis of various corneal diseases. The biomechanical characteristics of a connective tissue such as strength and resistance against mechanical stress are indispensable prerequisites to maintain regular shape and function of that tissue. Intraand intermolecular cross-links betwee...
متن کاملIn vivo biomechanical changes after corneal collagen cross-linking for keratoconus and corneal ectasia: 1-year analysis of a randomized, controlled, clinical trial.
PURPOSE To investigate the in vivo, corneal, biomechanical changes after corneal collagen cross-linking (CXL) using the Ocular Response Analyzer (ORA) in patients with keratoconus and post-laser in situ keratomileusis (LASIK) ectasia. METHODS Single-center, prospective, randomized, controlled, clinical trial. After CXL (69 eyes, 46 keratoconus and 23 post-LASIK), corneal hysteresis (CH) and c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 51 8 شماره
صفحات -
تاریخ انتشار 2010