Energy titration strategies with the endoscopic ablation system: lessons from the high-dose vs. low-dose laser ablation study.

نویسندگان

  • Stefano Bordignon
  • Kyoung-Ryul Julian Chun
  • Melanie Gunawardene
  • Verena Urban
  • Mehmet Kulikoglu
  • Kristin Miehm
  • Beate Brzank
  • Britta Schulte-Hahn
  • Bernd Nowak
  • Boris Schmidt
چکیده

AIMS To assess the effects of low-dose (LD) and high-dose (HD) ablation on acute and chronic success in patients with atrial fibrillation (AF). While the concept of visually guided pulmonary vein isolation (PVI) has been established little is known on energy titration using laser ablation. METHODS AND RESULTS In 60 patients with AF, PVI using the endoscopic ablation system (EAS) was performed in two groups. Visually guided ablation was carried out after obtaining optimal tissue contact with 5.5-8.5 W in the LD group and with >8.5 W in the HD group. Acute PVI after a single visually guided circular lesion set was achieved in 89% (HD) and 69% (LD), respectively, (P = 0.0004). In 70 and 39% of patients all PVs were isolated after a single ablation circle in the HD and LD group, respectively, (P = 0.009). After gap ablation all PVs were isolated with the EAS. More energy was deployed (6483 ± 1834 vs. 5306 ± 2258 Ws; P ≤ 0.0001) with less applications (31.6 ± 8 vs. 35.2 ± 15 applications per PV; P = 0.03) leading to shorter procedure times (128 ± 17 vs. 154 ± 38 min; P = 0.001). During median follow-up of 311 days (261-346) recurrence rate was 17 and 40% in the HD and LD group, respectively. In both groups one phrenic nerve palsy was observed. CONCLUSION For the first time, it was demonstrated that high ablation power affects acute and chronic outcomes. High-dose laser balloon ablation allows for an acute PVI rate of 89% solely by visually guided circular ablation and is associated with a chronic success rate of 83% after a single procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial neuroendocrine tumour metastasis mimicking melanoma: multimodality imaging diagnosis.

Tilz RR et al. Impact of pulmonary vein anatomy assessed by cardiac magnetic resonance imaging on endo-scopic pulmonary vein isolation in consecutive patients. Impact of pharmacological autonomic blockade on complex fractionated atrial electrograms. A et al. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vei...

متن کامل

Impact of energy titration in endoscopic pulmonary vein isolation.

Electrical isolation of the pulmonary veins (PVs) is the cornerstone in ablation of atrial fibrillation (AF). Radiofrequency current applied in a point-by-point fashion in combination with a threedimensional anatomical mapping system is the most frequent approach. The limitations of radiofrequency-based PV isolation (PVI) kindled interest in investigating the alternative energy sources and deve...

متن کامل

Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran

Introduction: Today electrophysiology studies and ablation have been developed due to increasing arrhythmias disorder of heart. In these diagnostic – treatments methods, the use of fluoroscopy can be causes patient radiation dose, therefore evaluation of patient's absorbed dose is necessary to protection of the radiation. The aim of this study was to evaluate the absorbed dose in patients under...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Magnetic Measurements of Graphene and Defected Graphene Generated by Laser Ablation Method

In this paper, the magnetic properties of carbon based material, graphene is studied, which is generated by laser ablation in cryogenic media. Transmission electron microscopy (TEM) and alternating gradient force magnetometer (AGFM) are applied to investigate the graphene morphology and magnetic properties, respectively. The graphene synthesized by the laser ablation method exhibits diamagnetic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 2013