Medical compression: effects on pulsatile leg blood flow.
نویسندگان
چکیده
AIM Leg compression bandaging is the mainstay of venous ulcer treatment, yet little is known about the impact of therapeutic compression levels on arterial haemodynamics. In this study, the effect of foot-to-knee, four-layer compression bandaging on below-knee arterial pulsatile blood flow was assessed by nuclear magnetic resonance flowmetry. METHODS In 14 healthy supine subjects, bilateral pulsatile blood flow measured at five below-knee sites without compression; and during compression of one leg to an average malleolar sub-bandage pressure of 40.7±4.0 mmHg. RESULTS The forefoot-to-knee compression bandaging caused a highly significant (P<0.001) increase in the bandaged leg pulsatile blood flow due to increases in both peak flow and pulse width. CONCLUSION It is hypothesized that arteriolar vasodilatation, induced either myogenically by reduced transmural pressure or by vasodilatory substance release triggered by increased venous shear stress and veno-arterial interactions, possibly combined with altered vascular compliance, produce the observed compression-related phenomenon. Whatever the mechanism(s), the finding of a compression-associated pulsatile flow increase suggests an arterial linkage, which may play a role in the well-documented beneficial effects of compression bandaging in venous ulcer and lymphedema treatment. Possible beneficial effects of the arterial flow-pulse increase on venous ulcer outcome may be related to a decrease in leukocyte effects in the distal microvasculature.
منابع مشابه
Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction
Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...
متن کاملPULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW
Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...
متن کاملAn implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملEffects of Intermittent Pneumatic Compression on Reduction of Postoperative Lower Extremity Edema and Normalization of Foot Microcirculation Flow in Patients Undergoing Arterial Revascularization
BACKGROUND In patients with chronic leg ischemia, the beneficial effect of arterial revascularization can be significantly decreased due to postoperative leg swelling. The aim of this study was to assess the effects of intermittent pneumatic compression (IPC) on skin flow normalization in patients undergoing revascularization procedures due to chronic leg ischemia. MATERIAL AND METHODS We evalu...
متن کاملEffect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International angiology : a journal of the International Union of Angiology
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2010