Metabolic Imaging of Human Kidney Triglyceride Content: Reproducibility of Proton Magnetic Resonance Spectroscopy

نویسندگان

  • Sebastiaan Hammer
  • Aiko P. J. de Vries
  • Paul de Heer
  • Maurice B. Bizino
  • Ron Wolterbeek
  • Ton J. Rabelink
  • Joost Doornbos
  • Hildo J. Lamb
چکیده

OBJECTIVE To assess the feasibility of renal proton magnetic resonance spectroscopy for quantification of triglyceride content and to compare spectral quality and reproducibility without and with respiratory motion compensation in vivo. MATERIALS AND METHODS The Institutional Review Board of our institution approved the study protocol, and written informed consent was obtained. After technical optimization, a total of 20 healthy volunteers underwent renal proton magnetic resonance spectroscopy of the renal cortex both without and with respiratory motion compensation and volume tracking. After the first session the subjects were repositioned and the protocol was repeated to assess reproducibility. Spectral quality (linewidth of the water signal) and triglyceride content were quantified. Bland-Altman analyses and a test by Pitman were performed. RESULTS Linewidth changed from 11.5±0.4 Hz to 10.7±0.4 Hz (all data pooled, p<0.05), without and with respiratory motion compensation respectively. Mean % triglyceride content in the first and second session without respiratory motion compensation were respectively 0.58±0.12% and 0.51±0.14% (P = NS). Mean % triglyceride content in the first and second session with respiratory motion compensation were respectively 0.44±0.10% and 0.43±0.10% (P = NS between sessions and P = NS compared to measurements with respiratory motion compensation). Bland-Altman analyses showed narrower limits of agreement and a significant difference in the correlated variances (correlation of -0.59, P<0.05). CONCLUSION Metabolic imaging of the human kidney using renal proton magnetic resonance spectroscopy is a feasible tool to assess cortical triglyceride content in humans in vivo and the use of respiratory motion compensation significantly improves spectral quality and reproducibility. Therefore, respiratory motion compensation seems a necessity for metabolic imaging of renal triglyceride content in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content.

PURPOSE To investigate reproducibility of proton magnetic resonance spectroscopy ((1)H-MRS) to measure hepatic triglyceride content (HTGC). MATERIALS AND METHODS In 24 subjects, HTGC was evaluated using (1)H-MRS at 3.0 Tesla. We studied "between-weeks" reproducibility and reproducibility of (1)H-MRS in subjects with fatty liver. We also studied within liver variability and within day reproduc...

متن کامل

Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method.

The primary aim of this investigation was to determine the reliability and sensitivity of 1H magnetic resonance spectroscopy (1H-MRS) as a method for quantifying myocardial triglyceride (TG) content in humans over time and in response to metabolic perturbations. Three separate experiments were designed to quantify myocardial TG content 1) over a 90-day period, 2) after a high-fat meal, and 3) a...

متن کامل

Association between Myocardial Triglyceride Content and Cardiac Function in Healthy Subjects and Endurance Athletes

Ectopic fat accumulation plays important roles in various metabolic disorders and cardiovascular diseases. Recent studies reported that myocardial triglyceride (TG) content measured by proton magnetic resonance spectroscopy ((1)H-MRS) is associated with aging, diabetes mellitus, and cardiac dysfunction. However, myocardial TG content in athletes has not yet been investigated. We performed (1)H-...

متن کامل

Innovative Methodology Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method

Reingold, Jason S., Jonathan M. McGavock, Shaheen Kaka, Tommy Tillery, Ronald G. Victor, and Lidia S. Szczepaniak. Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method. Am J Physiol Endocrinol Metab 289: E935–E939, 2005. First published June 21, 2005; doi:10.1152/ajpendo.00095.2005.—The primary aim of this invest...

متن کامل

Fatty Acid Metabolic Defects and Right Ventricular Lipotoxicity in Human Pulmonary Arterial Hypertension.

BACKGROUND The mechanisms of right ventricular (RV) failure in pulmonary arterial hypertension (PAH) are poorly understood. Abnormalities in fatty acid (FA) metabolism have been described in experimental models of PAH, but systemic and myocardial FA metabolism has not been studied in human PAH. METHODS AND RESULTS We used human blood, RV tissue, and noninvasive imaging to characterize multipl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013