Determinants of coronary remodeling in transplant coronary disease: a simultaneous intravascular ultrasound and Doppler flow study.

نویسندگان

  • S P Schwarzacher
  • N G Uren
  • M R Ward
  • A Schwarzkopf
  • N Giannetti
  • S Hunt
  • P J Fitzgerald
  • S N Oesterle
  • A C Yeung
چکیده

BACKGROUND Coronary remodeling plays a significant role in lumen loss in transplant allograft vasculopathy (TxCAD), but the determinants of remodeling are unknown. We assessed the relationship between remodeling and plaque topography, coronary compliance, and blood flow in TxCAD. METHODS AND RESULTS One artery in each of 27 transplant patients was investigated with simultaneous intravascular ultrasound and coronary flow measurements (basal and hyperemic by Doppler flow wire). At 4 to 8 different cross sections (mean 5.1+/-1. 2), plaque topography (concentric or eccentric) was determined, and total vessel area, lumen area, and intimal/medial area (IMA) were measured. Mean remodeling ratio (vessel area/IMA) in eccentric lesions (E, n=28) was significantly larger than that in concentric lesions (C, n=70) (E 5.87+/-0.93 versus C 3.58+/-0.62; P<0.001), despite similar IMA (E 3.89+/-0.68 versus C 3.90+/-0.41; P=NS) and distribution of imaged segments. Remodeling ratio was consistently larger in eccentric lesions in all 3 vessel segments when analyzed separately, and mean remodeling ratio for each artery was larger in vessels with predominantly eccentric lesions. Coronary compliance ([Delta lumen area/diastolic lumen area]/Delta mean arterial pressure x 10(3)) was also significantly greater in eccentric lesions versus concentric lesions (proximal 1.00+/-0.39 versus 0.22+/-0.04; mid 0.71+/-0.17 versus 0.21+/-0.10; distal 0.43+/-0.13 versus 0. 01+/-0.08; all P<0.01). Coronary flow reserve was also significantly higher in coronary arteries with primarily eccentric lesions (E 2. 49+/-0.64 versus C 1.87+/-0.28; P<0.01). CONCLUSIONS Vessel remodeling in transplant vasculopathy is significantly greater in eccentric lesions than in concentric lesions, possibly due to greater coronary compliance and resistive vessel function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endothelial dysfunction early after heart transplantation. Assessment with intravascular ultrasound and Doppler.

BACKGROUND Allograft vasculopathy after heart transplantation is thought to represent a response to endothelial injury in the graft vessels. To assess endothelial function before the onset of anatomic disease, coronary vasomotor responses to adenosine, acetylcholine, and nitroglycerin were evaluated in transplant recipients by intravascular ultrasound imaging and Doppler flow studies. METHODS...

متن کامل

Atrial pathology in cardiac amyloidosis: evidence from ECG and cardiovascular magnetic resonance.

Eaton GM, Lauer MA, Sheldon WS, Grines CL, Halpern S, Crowe T, Blankenship JC, Kerensky R. Effect of recombinant ApoA-I Milano on coronary atherosclerosis in patients with acute coronary syndromes: a randomized controlled trial. JAMA 2003;290:2292–2300. 14. Di Mario C, Gorge G, Peters R, Kearney P, Pinto F, Hausmann D, von Birgelen C, Colombo A, Mudra H, Roelandt J, Erbel R. Clinical applicatio...

متن کامل

Non-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis

In this study, a method for non-invasive estimation of stress on the heart wall in  the diastole phase is presented using ultrasound echocardiography and tissue Doppler  imaging. The aim of this study was to evaluate the stress on the heart wall as a  pre-diagnosis  to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...

متن کامل

Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients: Physiologic Investigation for Transplant Arteriopathy (PITA Study).

BACKGROUND The utility of measuring fractional flow reserve (FFR) to assess cardiac transplant arteriopathy has not been evaluated. Measuring coronary flow reserve (CFR) as well as FFR could add information about the microcirculation, but until recently, this has required two coronary wires. We evaluated a new method for simultaneously measuring FFR and CFR with a single wire to investigate tra...

متن کامل

Coronary Endothelial Function in Cardiac Transplant Recipients Relation to Vessel Wall Morphology

Background Coronary endothelial vasodilator dysfunction is a common finding in cardiac transplant recipients and may represent an early marker for the development of intimal thickening and graft atherosclerosis. The present study tested the hypothesis that endothelial dysfunction precedes intimal thickening and that administration of L-arginine, the precursor of endothelium-derived relaxing fac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 101 12  شماره 

صفحات  -

تاریخ انتشار 2000