Routine use of a V/Q SPECT/low-dose CT hybrid system to diagnose pulmonary embolism seems premature.

نویسنده

  • Ulf Nyman
چکیده

TOTHE EDITOR: Gutte et al. (1) reported on a novel, exciting concept to diagnose pulmonary embolism (PE) using a g-camera integrated with a multidetector CT scanner. Interestingly, ventilation–perfusion (V/Q) SPECT alone had almost a 20% false-positive rate caused by interlobar fissures, pleural fluid, and pulmonary pathology, whereas CT of the pulmonary arteries (CTPA) had a 100% positive predictive value. This finding emphasizes that, like a conventional V/Q scan, a V/Q SPECT scan showing mismatched defects requires a recent chest radiograph or preferably a low-dose pulmonary CT (LDCT) scan, conveniently performed with the author’s hybrid scanner. However, the value of the reported superior sensitivity of SPECT/LDCT relative to CTPA, and the drawbacks of CTPA due to renal impairment and radiation dose, may be debatable. One hundred ninety-six patients were recruited during 20 mo, a remarkably low figure for the 2 hospitals mentioned. At the same time, 24% of the patients were excluded because of renal impairment. To me, this indicates that some kind of additional selection criteria were applied in choosing from among the general cohort of patients with suspected PE. For comparison, only 0.7% of patients were excluded because of a glomerular filtration rate of less than 30 mL/min in the large, multicenter Christopher study (2). It should also be noted that CTPA in azotemic patients may be performed with substantially lower contrast medium doses (3,4) than in the present study, therefore disqualifying only a minority of patients for CTPA. Seven percent of the patients were excluded from CTPA because they were women less than 40 y old. The relatively high effective radiation dose (11 mSv) with the present CTPA protocol may have been the motive. The 2007 Fleischner Society Statement (5), representing a certain expertise in PE diagnosis, indicates that exposure parameters resulting in an effective dose as low as 3–5 mSv is sufficient for an adequate study. In fact, 80to 100-kVp CTPA with effective doses in the same range as (3.3 mSv) (6) or actually lower than (1.3–2.3 mSv) (6–8) that of the present SPECT/LDCT (3 mSv) have been achieved with preserved or even improved diagnostic quality. A composite reference standard including the index tests, that is, V/Q SPECT and CTPA, was used by Gutte et al. (1). This choice may introduce incorporation bias (item 7 in the Quality Assessment of Diagnostic Accuracy Studies [QUADAS]) overestimating the various measures of diagnostic accuracy (9). Specifically, mismatched defects of any size and number at V/Q SPECT may then have been taken as evidence of PE, partly explaining the relatively low sensitivity of CTPA while false-positive diagnoses at SPECT/LDCT may still have been present. To the best of my knowledge, there is to date not a single prospective study published adhering to the Standards for the Reporting of Diagnostic Accuracy Studies (STARD) (10), where defined SPECT criteria for a positive diagnosis of PE has been validated with a proper reference standard. Thus, the probability of PE, depending on the size and number or segmental equivalents of mismatched defects on SPECT combined with various clinical likelihoods of PE, is not known. One may also speculate on whether the high sensitivity of SPECT may diagnose PE that does not need anticoagulation. Several well-conducted outcome CTPA studies (2,11–13) clearly demonstrate that patients with clinically likely PE or a positive D-dimer, with few exceptions, can safely be left without anticoagulation after a negative CTPA result, even if not combined with ultrasonography of the lower legs (14). Thus, the lower sensitivity of CTPA may actually be advantageous relative to SPECT, which may carry the risk of serious bleeding complications from treatment of clinically harmless PE. The potential problem with falsepositive and harmless true-positive PE at SPECT/LDCT may not be solved unless we study the outcome of patients with mismatched SPECT/LDCT defects left without anticoagulation after a negative CTPA result. In conclusion, although having interesting potential in diagnosing PE, hybrid SPECT/LDCT is still a research tool and has to undergo properly performed studies based on the STARD and QUADAS criteria before it can be recommended as the “first-line imaging test in the work-up of PE in most cases.” The drawbacks of CTPA relative to SPECT/LDCT, with regard to contrast media and radiation, are today of minimal concern in nonpregnant patients (15) if contrast media and radiation exposure parameters are optimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography.

UNLABELLED The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have high diagnostic accuracy. However, only limited data directly comparing these 2 modalities...

متن کامل

V/Q scanning using SPECT and SPECT/CT.

Planar ventilation-perfusion (V/Q) scanning is often used to investigate pulmonary embolism; however, it has well-recognized limitations. SPECT overcomes many of these through its ability to generate 3-dimensional imaging data. V/Q SPECT has higher sensitivity, specificity, and accuracy than planar imaging and a lower indeterminate rate. SPECT allows for new ways to display and analyze data, su...

متن کامل

Combined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship

Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...

متن کامل

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis.

BACKGROUND Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. OBJECTIVES The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/CT(Q) with planar(Q) and SPECT(Q) methods. METH...

متن کامل

The Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis

Background: Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. Objectives: The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/ CT(Q) with planar(Q) and SPECT(Q) methods. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 51 8  شماره 

صفحات  -

تاریخ انتشار 2010