Comparison of m-Endo LES, MacConkey, and Teepol media for membrane filtration counting of total coliform bacteria in water.
نویسندگان
چکیده
Total coliform counts obtained by means of standard membrane filtration techniques, using MacConkey agar, m-Endo LES agar, Teepol agar, and pads saturated with Teepol broth as growth media, were compared. Various combinations of these media were used in tests on 490 samples of river water and city wastewater after different stages of conventional purification and reclamation processes including lime treatment, and filtration, active carbon treatment, ozonation, and chlorination. Endo agar yielded the highest average counts for all these samples. Teepol agar generally had higher counts then Teepol broth, whereas MacConkey agar had the lowest average counts. Identification of 871 positive isolates showed that Aeromonas hydrophila was the species most commonly detected. Species of Escherichia, Citrobacter, Klebsiella, and Enterobacter represented 55% of isolates which conformed to the definition of total coliforms on Endo agar, 54% on Teepol agar, and 45% on MacConkey agar. Selection for species on the media differed considerably. Evaluation of these data and literature on alternative tests, including most probable number methods, indicated that the technique of choice for routine analysis of total coliform bacteria in drinking water is membrane filtration using m-Endo LES agar as growth medium without enrichment procedures or a cytochrome oxidase restriction.
منابع مشابه
Comparison of media for recovery of total coliform bacteria from chemically treated water.
Five broth media and two solid media were compared for their ability to quantitatively recover total coliform bacteria from chemically treated water. M-Endo LES and mT7 media were used in the membrane filter technique. Lauryl tryptose broth, lactose broth, presence-absence broth, lactose broth with twice the amount of lactose, and lauryl tryptose broth with twice the amount of sodium lauryl sul...
متن کاملElimination of overgrowth in delayed-incubation membrane filter test for total coliforms by m-ST holding medium.
Two holding media were compared for their effects on total coliform recovery by the delayed-incubation membrane filter procedure. LES-MF holding medium contains tryptone, m-Endo broth, dipotassium hydrogen phosphate, sodium benzoate, sulfanilamide, para-aminobenzoic acid, and cycloheximide (pH 7.0). m-ST holding medium contains ethanol, sodium monophosphate, dipotassium hydrogen phosphate, sulf...
متن کاملImproved membrane filtration method incorporating catalase and sodium pyruvate for detection of chlorine-stressed coliform bacteria.
In vitro pure culture studies were conducted on three different strains of Escherichia coli (K-12, EPA 00244, and SWEI) to determine the effect of chlorination on catalase activity. In each case, stationary-phase cells exhibited significant (P less than 0.001) reductions in enzyme activity following exposure to chlorine. Mean differences in activity between control and chlorine-stressed cells r...
متن کاملEvaluation of factors affecting the membrane filter technique for testing drinking water.
The following studies were done in response to questions regarding the adoption and use of the membrane filter (MF) technique for testing drinking water for the total coliform indicator group. A comparison with the most-probable-number technique showed that MF procedures with m-Endo agar LES were somewhat superior to the most-probable-number methods in terms of numbers of coliform organims reco...
متن کاملA new membrane filtration medium for simultaneous detection and enumeration of Escherichia coli and total coliforms.
Recovery of total coliforms and Escherichia coli on a new membrane filtration (MF) medium was evaluated with 25 water samples from seven states. Testing of the new medium, m-ColiBlue24 broth, was conducted according to a U.S. Environmental Protection Agency protocol. For comparison, this same protocol was used to measure recovery of total coliforms and E. coli with two standard MF media, m-Endo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied and environmental microbiology
دوره 38 3 شماره
صفحات -
تاریخ انتشار 1979