In vitro analysis of the cariogenic and erosive potential of paediatric antitussive liquid oral medications.
نویسندگان
چکیده
We evaluated in vitro the cariogenic and erosive potential of antitussive liquid oral medications for paediatric use. Fifteen paediatric liquid antitussives were sampled. The endogenous pH was evaluated by potentiometry, titratable acidity was measured according to the method adopted by the Association of Official Analytical Chemists, total soluble solids content (TSSC) readings were performed by Brix refractometry using the Abbé refractometer, and the total sugar content was determined according to the Fehling methodology. The experiments were performed in triplicate and the obtained data were entered in the Excel software, analyzed and presented by descriptive statistics (means and standard deviations). Endogenous pH values ranged from 2.49 ± 0.09 (Iodetox®) to 6.75 ± 0.005 (Carbocysteine®) and twelve medications showed pHs below the critical value of 5.5 for enamel demineralization. Iodetox® (0.021 ± 0.01) presented the lowest titratable acidity and Aerofrin® (1.171 ± 0.01) presented the highest titratable acidity. Celergin® presented the highest TSSC (62.26 ± 0.40) and Acetyleysteine® (100 mg granules bags) presented the lowest TSSC (3.25 ± 0.43). Only 5 medications contained sugar, with total sugar content ranging from 35.93% ± 6.65 (Iodetox®) to 59.60% DP ± 6.66 (Celergin®). The paediatric antitussive medications showed low endogenous pH, some of them even below the critical value for enamel dissolution (pH<5.5). These antitussives are potentially cariogenic and erosive to dental structures if used frequently because of the high titratable acidity and high sugar concentration, especially when adequate oral clearance is not performed after administration of each dose.
منابع مشابه
Erosive and cariogenicity potential of pediatric drugs: study of physicochemical parameters
BACKGROUND Pediatric medications may possess a high erosive potential to dental tissues due to the existence of acid components in their formulations. The purpose was to determine the erosive and cariogenic potential of pediatric oral liquid medications through the analysis of their physicochemical properties in vitro. METHODS A total of 59 substances were selected from the drug reference lis...
متن کاملComparative evaluation of cariogenic and erosive potential of commonly prescribed pediatric liquid medicaments: an in vitro study.
INTRODUCTION Liquid oral medicines being the most accepted form of medication in children are frequently prescribed. The harmful effects of these liquid medicaments on a child's dental health are not known to many. The present study aimed to evaluate and compare the cariogenic and erosive potential of 5 most commonly prescribed pediatric liquid medicaments (PLM) in Pimpri Chinchwad and Pune cit...
متن کاملEvaluation of the Erosive Potential of Various Pediatric Liquid Medicaments: An in-vitro Study.
BACKGROUND The present in-vitro study was a scanning electron microscope (SEM) study conducted in primary teeth in order to evaluate the erosive potential of ten commonly used pediatric liquid medications (PLMs). MATERIALS & METHODS 10 commonly used PLMs and 33 exfoliated or extracted primary teeth were collected. The 33 teeth were divided into two groups, the control group (n=3) and the stud...
متن کامل[Perceptions and attitudes among parents and guardians on the use of pediatric medicines and their cariogenic and erosive potential].
The study assesses the perceptions of parents/guardians on the use of pediatric medicines and their cariogenic/erosive potential, interviewing them on the relationship between the use of pediatric medicines and cavities/dental erosion, as well as oral hygiene procedures after the medication. Among the interviewed parents/guardians (n=86), 24 (27.9%) mentioned the sour taste of pediatric medicat...
متن کاملAssessment of Plaque pH after Oral Rinsing with Four Customary Used Types of Complementary Infant Formula
Background: Complementary infant formulas are the second most important sources of nutrition for neonates after breast milk. Considering the cariogenic potential of infant formulas, selection of these nutritive sources should be safe to reduce the risk of baby bottle syndrome in newborns. The present study aimed to estimate the plaque pH changes after rinsing with four customary used types of c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Tanzania journal of health research
دوره 14 2 شماره
صفحات -
تاریخ انتشار 2012