Bispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.
نویسندگان
چکیده
BACKGROUND Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. METHODS Patients undergoing surgery with local or regional anesthesia and sedation were randomized to sevoflurane (n = 23), midazolam (n = 21), or propofol (n = 22). Sedation was titrated to Observers's Assessment of Alertness-Sedation score of 3 (responds slowly to voice). BIS and Observers's Assessment of Alertness-Sedation were measured every 5 min. BIS prediction probability (PK) was compared between drugs. Recovery was assessed by BIS and Digit Symbol Substitution and memory tests. RESULTS Bispectral Index of responders to voice was significantly different from nonresponders (86 +/- 10 vs. 74 +/- 14, mean +/- SD; P < 0.001) However, wide variability and overlap in BIS were observed (25th-75th percentile, responders vs. non-responders: 79-96 vs. 65-83). BIS of responders was different for sevoflurane versus propofol and midazolam. BIS was a better predictor of propofol sedation than sevoflurane or midazolam (PK = 0.87 +/- 0.11, 0.76 +/- 0.01, and 0.69 +/- 0.02, respectively; P < 0.05). At 10 min after the procedure, 76, 48, and 24% of sevoflurane, propofol, midazolam patients, respectively, returned to baseline Digit Symbol Substitution scores (P < 0.05). Excitement-disinhibition occurred in 70, 36, and 5% of sevoflurane, propofol, and midazolam patients, respectively (P < 0.05). CONCLUSION Individual BIS scores demonstrate significant variability, making it difficult to predict sedation depth. The relation between BIS and sedation depth may not be independent of anesthetic agent. Quality of recovery was similar between drugs, but excitement occurred frequently with sevoflurane.
منابع مشابه
Efficacy of Bispectral Index Monitoring for Midazolam and Meperidine Induced Sedation during Endoscopic Submucosal Dissection: A Prospective, Randomized Controlled Study
BACKGROUND/AIMS Propofol induced sedation with bispectral index (BIS) monitoring has been reported to lead to higher satisfaction in patients and endoscopists during endoscopic submucosal dissection (ESD) procedures. There are no data, however, regarding the efficacy of midazolam and meperidine (M/M) induced sedation with BIS monitoring during ESD. The purpose of this study was to evaluate whet...
متن کاملExtreme intraoperative blood loss and hemodilution in a Jehovah's Witness: new aspects in postoperative management.
1. Rosow C, Manberg PJ: Bispectral Index Monitoring. Anesthesiology Clinics of North America: Ann Anesth Pharmacol 1998; 2:89–107 2. Glass P, Bloom M, Kearse L, Rosow C, Sebel P, Manberg P: Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfenanil in healthy volunteers. ANESTHESIOLOGY 1997; 86:836–47 3. England MR, Murphy MC, Court M: How much is...
متن کاملAmnesia for electric dental pulp stimulation and picture recall test under different levels of propofol or midazolam sedation.
AIM To compare the amnesic effect of propofol and midazolam to electric dental pulp stimulation (invasive) and picture recall test (non-invasive) at two sedation levels with the aid of bispectral index (BIS) monitoring. METHODS The subjects were 10 male volunteers (24-34 years) classified as ASA physical status I. Propofol was administered to achieve a sedation score of three with a target-co...
متن کاملChanges in the rapidly extracted auditory evoked potentials index and the bispectral index during sedation induced by propofol or midazolam under epidural block.
BACKGROUND The bispectral index (BIS) and the rapidly extracted auditory evoked potentials index (A-line ARX Index or AAI) have been proposed as methods to measure the depth of sedation. A prospective study was designed to assess the performance of both these methods for measuring the depth of sedation induced by propofol or midazolam under epidural block. METHODS Thirty-two ASA I and II adul...
متن کاملLow bispectral index values in awake volunteers receiving a combination of propofol and midazolam.
THE Bispectral Index (BIS) is increasingly used to monitor the level of (un)consciousness during surgical anesthesia and conscious sedation. Generally, an intraoperative BIS of 40–60 is considered sufficient to maintain adequate hypnosis for surgery. Recently, a new version of the BIS monitor has been introduced: the BIS-XP (Aspect Medical Systems, Newton, MA). The BIS-XP is said to exhibit imp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesiology
دوره 95 5 شماره
صفحات -
تاریخ انتشار 2001