Clinical application of a novel endoscopic mask: a randomized controlled, multi-center trial in patients undergoing awake fiberoptic bronchoscopic intubation

نویسندگان

  • Tianxiao Zou
  • Zhenling Huang
  • Xiaoxue Hu
  • Guangyu Cai
  • Miao He
  • Shanjuan Wang
  • Ping Huang
  • Bin Yu
چکیده

BACKGROUND Awake fiberoptic bronchoscopic tracheal intubation is usually regarded as an effective method in the management of predicted difficult airway. Hypoxia during awake nasal fiberoptic bronchoscopic intubation leads to discontinuation of the procedure, prolonged manipulation time and increased risk of severe complications. The main aim of the study was to test whether the novel endoscopic mask is helpful for hypoxia during the intubation. METHODS This was a randomized, controlled, multi-center study. 55 patients were recruited, but one patient was lost to follow-up. Finally, 54 patients (19 man and 35 women) were analyzed. After entering the operating room, nasal catheter oxygen-providing was given in the control group, and the treatment group received endoscopic mask oxygen-providing, with a flow rate of 3 L/min, lasting into the end of the intubation. Primary outcomes included mean arterial pressure, heart rate, minimum pulse oxygen saturation and incidence of pulse oxygen saturation ≤ 90%. Secondary outcomes included number of intubation attempts and time to intubation. All outcomes were finally measured. RESULTS Minimum pulse oxygen saturation during awake nasal fiberoptic bronchoscopic tracheal intubation was significantly higher in the endoscopic mask intubation group (91.7% ± 4.7%) than that the nasal catheter intubation group (87.6% ± 8.2%, P = 0.031. Furthermore, the incidence of pulse oxygen saturation ≤ 90% was significantly lower in the endoscopic mask intubation group (20.0%, 5/25) than that in the nasal catheter intubation group (51.7%, 15/29, P = 0.037). But mean arterial pressure of during intubation was significantly higher in the endoscopic mask group (100.0 ± 13.3 vs 90.3 ± 21.8, P = 0.049). In addition, there were no differences in the number of intubation attempts (P = 0.45) or time to intubation between the two groups (P = 0.38). CONCLUSIONS The endoscopic mask was safely used in awake fiberoptic bronchoscopic tracheal intubation, with advantages of stable blood pressure and potential prevention of desaturation. Beginners for the intubation procedure and patients at high risk of hypoxia could benefit from the use of the endoscopic mask. TRIAL REGISTRATION Trial registration: www.chictr.org.cn . Registration No.: ChiCTR-TRC-13004086. Date of Registration: 8th, Sep, 2013.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Incidence of Sore Throat and Hemodynamic Changes in ‎Airway Management by Macintosh, Glideoscope Laryngoscope and ‎Laryngeal Mask Airway Techniques: Randomized Controlled Trial

Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway  techniques in elective surg...

متن کامل

Effectiveness and Safety of a Novel Approach for Management of Patients with Potential Difficult Mask Ventilation and Tracheal Intubation: A Multi-center Randomized Trial

Background: Patients with potential difficult mask ventilation (DV) and difficult intubation (DI) are often managed with awake intubation, which can be stressful for patients and anesthesiologists. This prospective randomized study evaluated a new approach, fast difficult airway evaluation (FDAE). We hypothesized that the FDAE approach would reduce the need for awake intubation. Methods: Afte...

متن کامل

Clinical application of a novel endoscopic mask: A randomized controlled trial in aged patients undergoing painless gastroscopy

Background: Desaturation during painless gastroscopy in aged patients leads to discontinuation of the procedure, prolonged manipulation time and increased risk of severe complications. An endoscopic nasal mask was designed to control hypoxia during the above procedures. A randomized trial was performed to test whether the novel endoscopic mask is helpful for hypoxia during painless gastroscopy ...

متن کامل

Authors’ Reply to Letter to the Editor “Comparing Sedation Regimens for Awake Fiberoptic Intubation”

There are no conflicts of interest. midazolam versus Sufentanil‑midazolam for awake fiberoptic nasotracheal intubation: A randomized double‑blind study. effective dose of remifentanil for awake laryngoscopy and intubation. airway topical anesthesia in patients with a difficult airway: A randomized, double‑blind comparison of 2% and 4% lidocaine. Comparison of dexmedetomidine and sufentanil for ...

متن کامل

Comparison of Effectiveness of Betamethasone gel Applied to the Tracheal Tube and IV Dexamethasone on Postoperative sore Throat: A Randomized Controlled Trial

Introduction: Postoperative sore throat is a common complaint in patients with endotracheal intubation and has potentially dangerous complications. This randomized controlled trial study investigated the incidence of postoperative sore throat after general anesthesia when betamethasone gel is applied to a tracheal tube compared with when IV dexamethasone is prescribed.   Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017