Comparison of two quantitative hepatitis C virus reverse transcriptase PCR assays.

نویسندگان

  • W K Roth
  • J H Lee
  • B Rüster
  • S Zeuzem
چکیده

A quantitative hepatitis C virus reverse transcriptase PCR (HCV RT-PCR) assay established in our laboratory was compared with the Roche Amplicor HCV Monitor test kit for agreement of test results and intra-assay variability. Both assays rely on reverse transcription and amplification of extracted RNA from patients' sera together with an internal RNA standard derived from the 5'-noncoding region of HCV. A panel of clinical serum samples (n = 33) was quantitatively analyzed in parallel by both test systems. The methods demonstrated substantial agreement between 1 x 10(3) and 5 x 10(5) HCV RNA molecules per ml of serum. However, with sera containing more than 5 x 10(5) copies per ml, according to our in-house assay, the results diverged on average in a nonacceptable range of 2 orders of magnitude. Our in-house HCV RT-PCR assay measured up to 5 x 10(7) HCV-RNA molecules per ml in some serum samples. However, the Roche Amplicor HCV Monitor test kit did not detect more than 2 x 10(6) molecules in any of the serum samples tested. After dilution of serum samples prior to testing, an approximately 0.5 order of magnitude more HCV RNA molecules was detected by the Roche HCV test kit in sera containing high copy numbers (> 5 x 10(5) RNA copies according to the in-house assay). The in-house PCR and the Roche Amplicor HCV Monitor test kit revealed coefficients of variation of 6.2 and 7.5%, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency of Torque Teno Mini Virus in Hepatitis B and C Patients and Healthy Blood Donors in Isfahan, Iran

Background: Recently, some new viruses have been identified for their association with hepatitis which Torque Teno Mini Virus being among them. The aim of this study was to determine the frequency of Torque Teno Mini Virus in healthy individuals and hepatitis B and C patients in Isfahan, Iran. Materials and Methods: One hundred serum samples of healthy individuals from Isfahan Blood Transfusi...

متن کامل

Comparison of real-time reverse transcriptase PCR assays for detection of swine hepatitis E virus in fecal samples.

Hepatitis E virus (HEV) is a major cause of acute viral hepatitis in people in many developing countries and is also endemic in many industrialized countries. Mammalian HEV (mHEV) isolates can be divided into at least four recognized major genotypes. Several nucleic acid amplification techniques have been developed for mHEV detection, with great differences in sensitivity. The aim of this study...

متن کامل

Quantification of hepatitis C virus in human liver and serum samples by using LightCycler reverse transcriptase PCR.

A highly sensitive, non-probe-based, real-time quantitative reverse transcriptase PCR was developed for viral load measurements in both serum and liver samples from patients with hepatitis C virus (HCV) infection. With synthetic RNA, the linearity of the approach was conserved over a wide range of HCV copy numbers. There was a strong correlation between hepatic and serum viral load measurements...

متن کامل

Clinical characterization of a competitive PCR assay for quantitative testing of hepatitis C virus.

Rational clinical application of quantitative assessments of hepatitis C virus (HCV) RNA depends on an understanding of factors affecting the assay and its intrinsic variability. The effects of three types of blood collection tubes, two storage temperatures, five processing times, and two laboratories on a commercially available quantitative reverse transcriptase PCR assay (AMPLICOR HCV MONITOR...

متن کامل

Hepatitis C virus detection by single-round PCR specific for the terminal 3' noncoding region.

A single-round PCR method with primers specific for the 3' noncoding region (NCR) of hepatitis C virus (HCV) has been developed. Using a double RNAzol-B extraction, a high-temperature reverse-transcription step with SuperScript II reverse transcriptase, and a 40-cycle two-temperature PCR with a TaqStart antibody hot-start procedure, we were able to detect a 92-nucleotide fragment of the recentl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 1996