Simulation and Validation of a R404A/CO2 Cascade Refrigeration System

نویسندگان

  • Jonathan Michael Winkler
  • Vikrant Aute
  • Reinhard Radermacher
  • Doron Shapiro
  • Jon WINKLER
  • Vikrant AUTE
  • Reinhard RADERMACHER
چکیده

The interest in natural refrigerants, such as carbon dioxide, has been growing in recent years due to the high direct global warming potential of common HFC refrigerants. Despite the environment-friendly characteristics of CO2 as a refrigerant, due to high heat rejection temperatures and transcritical operation, CO2 cannot match the high energy efficiency associated with current HFC technology. Thus, additional measures must be taken to achieve high COP when using CO2. One approach is to use CO2 as one of the fluids in a cascade system along with a HFC refrigerant as the high side fluid. Such systems may have roughly 75% less HFC refrigerant charge, and the global warming potential is reduced compared to a baseline system using only HFC refrigerant. When used as a second fluid in a cascade system, the CO2 cycle remains in the subcritical region, thus increasing the cycle’s COP. In this paper an approach to model cascade systems is presented. The model is validated using experimental data for a R404A/CO2 cascade system and results are discussed. The simulation tool is developed to account for additional components in the system such as multiple condensers and compressors. Some test points in the experimental system were run using a set of parallel compressors, which can be easily addressed by the simulation tool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Simulation of R410a-R23 and R404A-R508B Cascade Refrigeration System

Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by a reduction in the evaporator temperature. The single stage vapour compression refrigeration system using various refrigerants are limited to an evaporator temperature of -40 0C. Below temperature of -40 0C the either cascade refrigeration sys...

متن کامل

Numerical Simulation of Heat Exchanger Area of R410A-R23 and R404A-R508B Cascade Refrigeration System at Various Evaporating and Condensing Temperature

Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by reduction in the evaporator temperature. The single stage vapour compression refrigeration system is limited to an evaporator temperature of -40 C. Below temperature of -40 C the either cascade refrigeration system or multi stage vapour compre...

متن کامل

Performance Evaluation and Optimal Design of Supermarket Refrigeration Systems with Supermarket Model “SuperSim”, Part II: Model Applications

As described in Part I, the supermarket simulation software “SuperSim” with its integrated refrigeration, building and HVAC system models, can be used to evaluate, compare and optimize alternative supermarket refrigeration systems. In Part II the model was used to evaluate and compare the performance of a CO2 booster refrigeration system with that of a conventional R404A multiplex system in a s...

متن کامل

Performance Evaluation and Optimal Design of Supermarket Refrigeration Systems with Supermarket Model “SuperSim”, Part I: Model Description and Validation

Conventional supermarket refrigeration systems are responsible for considerable CO2 emissions due to high energy consumption and large quantities of refrigerant leakage. In the effort to conserve energy and reduce environmental impacts, an efficient design tool for the analysis, evaluation and comparison of the performance of alternative system designs and controls is required. This paper provi...

متن کامل

Energy Analysis of Various Supermarket Refrigeration Systems

Modeling and analysis work was done on various supermarket refrigeration systems for their energy efficiency, TEWI (Total Equivalent Warming Impact), and annual operating cost. The systems which were modeled in detail include parallel racks, distributed, self-contained, glycol secondary loop, and CO2 secondary loop (medium temperature) and cascade (low temperature). Based on R404A modeling resu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014