Development of rapid and precise Pb isotope analytical techniques using MC-ICP-MS and new results for GSJ rock reference samples

نویسندگان

  • MASAHARU TANIMIZU
  • TSUYOSHI ISHIKAWA
چکیده

A rapid and precise routine Pb isotope analytical technique for rock samples was developed using multiple collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The mass discrimination of the Pb isotope ratios was corrected with the 205Tl/203Tl ratio of a Tl isotope reference material (NIST SRM 997) added to samples. The optimization of the analytical parameters and the minimization of the memory and matrix effects enabled to acquire the Pb isotope data rapidly (three samples per hour) with a reproducibility of 0.01% by consumption of 150 ng Pb per analysis. Repeated analyses of a Pb isotope reference material, NIST SRM 981, gave the average values of 206Pb/204Pb = 16.9308 ± 0.0010, 207Pb/204Pb = 15.4839 ± 0.0011, and 208Pb/204b = 36.6743 ± 0.0030 (2σ). Pb isotope ratios of eleven Geological Survey of Japan rock reference samples were determined using this technique. In anion-exchange chemical separation, complete removal of Hg and Tl from the Pb fraction was confirmed. It was revealed that the Tl-normalization minimized the matrix effects caused by remaining impurities and medium, and the reproducibility of seven independent analyses of JB-2 was comparable to that of NIST SRM 981. Pb isotope ratios obtained for the rock reference samples showed a good agreement with those given previously.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

From volcanic rock powder to Sr and Pb isotope ratios: a fit-for-purpose procedure for multi-collector ICP–mass spectrometric analysis

Geochemical research into volcanic rocks often involves isotopic analysis of whole rock powders. The method of Deniel and Pin (Anal. Chim. Acta, 2001, 426, 95-103) for simultaneous isolation of strontium and lead using extraction chromatography via Sr spec resin was therefore adapted into a straightforward procedure for Sr and Pb isotope ratio determination by multi-collector inductively couple...

متن کامل

A Review of Mg Isotope Analytical Methods by MC-ICP-MS

Application of multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) has led to big breakthrough of analytical methods for metal stable isotopes, resulting in rapid progresses in non-traditional stable isotope geochemistry. As a new geological tracer, Mg isotopes have been widely applied in studies of almost all important disciplines of geochemistry. High precision Mg isotope...

متن کامل

Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.

Electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (ETV-ID-ICP-MS) was applied to the determination of Cd and Pb in urine samples. The isotope ratios for each element in each analytical run were calculated from the peak areas of each isotope. A relatively low vaporization temperature was used, which separated the analyte from the major matrix components an...

متن کامل

ICP-MS determination of lead isotope ratios in legal and counterfeit cigarette tobacco samples.

A method for the determination of Pb isotope ratios (IR) in cigarette tobacco by quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) has been developed and applied to tobacco samples from genuine and counterfeit cigarettes obtained in the USA. The IR ²⁰⁷Pb/²⁰⁶Pb, (208)Pb/²⁰⁶Pb, ²⁰⁶Pb/²⁰⁴Pb, ²⁰⁷Pb/²⁰⁴Pb and ²⁰⁸Pb/²⁰⁴Pb were measured using a Q-ICP-MS instrument. Two certified refer...

متن کامل

Magnesium isotopic composition of igneous rock standards measured by MC-ICP-MS

Keyword: Mg isotopes Igneous rock standards MC-ICP-MS To provide inter-lab comparison for high-precision Mg isotope analysis, Mg isotope compositions (expressed as δMg relative to DSM-3) for commercially accessible peridotite, basalt, andesite, and granite geostandards have been measured by multi-collector inductively coupled mass-spectrometry (Nu-Plasma) using sample-standard bracketing method...