A Patient Care Program for Adjusting the Autoinjector Needle Depth According to Subcutaneous Tissue Thickness in Patients With Multiple Sclerosis Receiving Subcutaneous Injections of Glatiramer Acetate

نویسندگان

  • Maria Luisa Sánchez Masid
  • Rosalía Horno Ocaña
  • María Jesús Díaz Gil
  • Maria Concepción Ramírez Ramos
  • Matilde Escutia Roig
  • Maria Rosario Coll Carreño
  • Jaime Cordero Morales
  • Maria Luisa Vergara Carrasco
  • Leonor Mariana Rubio Hidalgo
  • Ana Maria Bernad Felices
  • Adela Harto Castaño
  • Purificación Castañeda Romero
  • Pablo Francoli Martinez
  • Rainel Sánchez-De la Rosa
چکیده

BACKGROUND The perceived pain on injection site caused by subcutaneous (SC) self-injection may negatively affect acceptance and adherence to treatment in patients with multiple sclerosis (MS). Pain on injection may be caused by inaccurate injection technique, inadequate needle length adjustment, or repeated use of the same injection body area. However, information is lacking concerning the optimal needle depth to minimize the injection pain. OBJECTIVE The purpose of this program was to characterize the perceived injection-site pain associated with the use of various injection depths of the autoinjector of glatiramer acetate (GA) based on SC tissue thickness (SCT) of the injection site. METHODS This was a pilot program performed by MS-specialized nurses in patients with MS new to GA. Patients were trained by MS nurses on the preparation and administration of SC injection and on an eight-site rotation (left and right arms, thighs, abdomen, and upper quadrant of the buttock). The needle length setting was selected based on SCT measures as follows: 4 or 6 mm for SCT < 25 mm, 6 or 8 mm for SCT between 25 and 50 mm, and 8 or 10 mm for SCT > 50 mm. Injection pain was rated using a visual analog scale (VAS) at 5- and 40-minute postinjection and during two 24-day treatment periods. RESULTS Thirty-eight patients with MS were evaluated. The mean SCT ranged from 15.5 mm in the upper outer quadrant of the buttocks to 29.2 mm in the thighs. The mean perceived pain on injection was below 3 for all the injection sites, at both time points (5 and 40 minutes) and during both 24-day evaluation periods. The mean VAS scores were significantly greater after 5 minutes of injection compared with that reported 40-minute postinjection during both 24-day treatment periods and for all the injection areas. Mean VAS measures at 5- and 40-minute postinjection significantly decreased during the second 24-day treatment period with respect to that reported during the first 24 SC injections for all injection sites. CONCLUSIONS Our findings suggest that the adjustment of injection depth of SC GA autoinjector according to SCT of body injection areas is suitable to maintain a low degree of postinjection pain. Moreover, our results also may indicate that the use of needle lengths of 6 mm or shorter is appropriate with regard to injection pain for adult patients with MS with SCT < 50 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Understanding and meeting injection device needs in multiple sclerosis: a survey of patient attitudes and practices

BACKGROUND All established disease-modifying drugs for multiple sclerosis require parenteral administration, which can cause difficulties for some patients, sometimes leading to suboptimal adherence. A new electronic autoinjection device has been designed to address these issues. METHODS Patients with relapsing multiple sclerosis currently receiving subcutaneous or intramuscular interferon be...

متن کامل

Survey of US Patients with Multiple Sclerosis: Comparison of the New Electronic Interferon Beta-1b Autoinjector (BETACONNECT™) With Mechanical Autoinjectors

INTRODUCTION Patients with multiple sclerosis (MS) generally undergo long-term treatment with disease-modifying therapies (DMTs). In the US, patients taking glatiramer acetate, interferon beta-1a, or interferon beta-1b, typically use a mechanical autoinjector. Recent survey results have shown that using an electronic autoinjector, such as BETACONNECT™ (Bayer Pharma AG) for interferon beta-1b/Be...

متن کامل

Localized panniculitis secondary to subcutaneous glatiramer acetate injections for the treatment of multiple sclerosis: a clinicopathologic and immunohistochemical study.

BACKGROUND Glatiramer acetate has been shown to be effective in reducing the relapse and improving the disability of patients with multiple sclerosis. The most common adverse effects at the injection sites include pain, inflammation, and induration that spontaneously disappear within hours or a few days. OBJECTIVE We sought to characterize the histopathologic findings of localized panniculiti...

متن کامل

Recurrent Nicolau syndrome associated with subcutaneous glatiramer acetate injection—a case report

BACKGROUND Glatiramer acetate is worldwide used as first line treatment in relapsing remitting multiple sclerosis. Local skin reactions associated with glatiramer acetate are common, however, only isolated cases of severe local injection site reactions known as Nicolau Syndrome have been reported so far. CASE PRESENTATION We describe the case of a recurrent Nicolau Syndrome occurred during lo...

متن کامل

29 gauge needles improve patient satisfaction over 27 gauge needles for daily glatiramer acetate injections

Using three surveys, a comparative assessment of needle performance and patient preference for 27-gauge (G) and 29G needles for glatiramer acetate administration for multiple sclerosis therapy was performed. Eligible patients participated in a specialty pharmacy program and administered glatiramer acetate for ≥1 month. In Survey 1 on the 27G needle, 545 (82.70%) patients reported no needle prob...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2015