Mean platelet volume is elevated in patients with patent foramen ovale

نویسندگان

  • Bulent Demir
  • Ilker Murat Caglar
  • Ismail Ungan
  • Murat Ugurlucan
  • Hande Oktay Tureli
  • Osman Karakaya
چکیده

INTRODUCTION Platelets play a major role in thromboembolic events. Increased mean platelet volume (MPV) indicates higher platelet reactivity and also a tendency to thrombosis. Patent foramen ovale (PFO), persistence of the fetal anatomic shunt between right and left atria, is strongly associated with cryptogenic stroke. The aim of this study is to determine the relationship between MPV and PFO and if such an association exists, whether higher MPV levels may require antiplatelet therapy before a thromboembolic event happens, together with a literature review. MATERIAL AND METHODS Thirty patients (15 women, 15 men), free of any cerebrovascular events, were diagnosed with PFO by transesophageal echocardiography (TEE), enrolled as the study group. Thirty consecutive patients (16 women and 14 men), who were diagnosed as normal in TEE, were enrolled as the control group. These two groups were compared according to MPV and anatomical features of the right atrium. RESULTS There was no significant difference between study and control groups in clinical features and also no difference was observed in platelet counts; however, MPV in the PFO group was significantly higher than the control group (8.38 ±0.93 fl and 7.45 ±0.68 fl respectively). CONCLUSIONS Our results indicate that elevated MPV may be detected in patients with PFO. This might be one of the explanations for the relationship between PFO and cryptogenic stroke; however, larger cohorts are warranted in order to define further mechanisms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decline in mean platelet volume in patients with patent foramen ovale undergoing percutaneous closure

INTRODUCTION The presence of patent foramen ovale (PFO) is considered a possible cause for cryptogenic stroke. The mechanism underlying the ischaemic neurological events in the presence of PFO has not been firmly established. The purpose of this study was to compare: (1) the mean platelet volume levels in PFO patients with and without a cryptogenic stroke, and (2) pre- and post-procedural mean ...

متن کامل

Heart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy

This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...

متن کامل

فراوانی آنومالی های سپتوم بین دهلیزی در بیماران با حوادث آمبولیک مغزی با علت ناشناخته با اکوکاردیوگرافی ترانس توراسیک و ترانس ازوفاژیال، بیمارستان امام تهران

Atrial septal anomalies suggested to play important role in enhancing tendency to induce cerebral embolic events. This study was undertaken to find the frequency of atrial septal anomalies including Patent Foramen Ovale, Atrial Septal Aneurysm and Atrial Septal Defect in patients with etiologically unknown stroke categorized as cryptogenic.Materials and Methods: 32 patients were studied by tran...

متن کامل

Hypoxemia secondary to right-to-left interatrial shunt through a patent foramen ovale in a patient with an elevated right hemidiaphragm.

Though uncommon, right-to-left shunt through a patent foramen ovale with normal right-side pressure and with a normal interatrial pressure gradient has been reported. The speculated pathophysiology is attributed to directional blood flow streaming from the vena cava to the left atrium. Hypoxemia secondary to right-to-left shunt with normal pulmonary artery pressure has been extensively document...

متن کامل

Microbubbles shunting via a patent foramen ovale impair endothelial function

OBJECTIVES Exposure to intravascular microbubbles after diving and during medical procedures alters endothelial function. The aim of this study was to investigate whether a patent foramen ovale altered forearm endothelial function by facilitating microbubbles transfer. DESIGN Patients attended on two separate visits, at least seven days apart receiving agitated saline or no active interventio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -