Rate of manual leukocyte differentials in dog, cat and horse blood samples using ADVIA 120 cytograms
نویسندگان
چکیده
BACKGROUND Modern automated haematology instruments are capable of performing leukocyte differentials faster, cheaper and with a higher precision than the traditional 100-cell manual differential count. Thus, in human laboratories, criteria are defined for performing a manual review of the blood smear resulting in a marked reduction of manual differential counts. While common in human laboratories, this approach to reducing the number of manual differentials in veterinary laboratories is still not commonly performed. Thus, our aim was to determine the rate and causes of manual leukocyte differentials in a university clinical pathology laboratory using the automated laser-based haematology analyser ADVIA 120. Overall, 14,953 complete blood cell counts from dogs, cats and horses were reviewed. Manual leukocyte differentials were requested if abnormal ADVIA peroxidase and baso cytograms were detected (i.e. suspicion of left shift or atypical lymphocytes/blasts, inappropriate separation of cell populations). RESULTS In 21% of canine, 32% of feline and 20% of equine samples, a manual differential was requested. Indistinct separation of the cell population was present in 10% to 15% of the cases. Depending on the species, atypical lymphocytes were suspected in 2% to 12%, left shift in 13% to 25% and suspicion of blasts was present in less than 0.4% of the cases. CONCLUSIONS The obtained results are comparable to those published for human medicine and the rate of manual differentiation could be markedly reduced in veterinary laboratories if microscopic examination was used as a validation procedure rather than as a reflexive substitute for automated differentiation.
منابع مشابه
Reference intervals for a complete blood count determined on different automated haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120.
We processed 317 samples from healthy adult volunteers for a complete blood count, including leukocyte differentials and reticulocyte parameters, through five new-generation haematology analysers: Abx Pentra 120 Retic, Coulter Gen-S, Sysmex SE 9500, Abbott Cell Dyn 4000 and Bayer Advia 120. From these data non-parametric 2.5-97.5 percentile reference intervals were calculated for all parameters...
متن کاملPerformance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial.
Automated cell counters are widely used in modern clinical laboratories to provide reliable, fast, and cost-effective complete blood counts (CBCs), white blood cell differentials, and reticulocyte measurements. In addition, some advanced instruments provide novel parameters, such as the hemoglobin content of reticulocytes or the percentage of hypochromic cells, and are capable of analysis of a ...
متن کاملChanges of hematological references depends on storage period and temperature conditions in rats and dogs
Because changes in rat and dog hematological parameters according to storage conditions have been poorly documented, we sought to examine such changes. Blood analysis was performed using two hematology analyzers (ADVIA 2120i and Sysmex XN-V) after storage at room temperature and in cold storage for 5, 24, and 48 h, respectively. Interassay coefficients of variation for hematological parameters ...
متن کاملComparison of automated differential blood cell counts from Abbott Sapphire, Siemens Advia 120, Beckman Coulter DxH 800, and Sysmex XE-2100 in normal and pathologic samples.
Reliable automated blood cell characterization and quantification remain challenging in pathologic samples, whereas slide reviews due to unnecessary flagging should be avoided. We compared 4 modern hematology analyzers-Abbott Sapphire, Siemens Advia 120, Sysmex XE-2100, and Beckman Coulter DxH 800-regarding complete blood cell count (CBC), leukocyte differential count, and flagging efficacy in ...
متن کاملIn silico identification of epitopes from house cat and dog proteins as peptide immunotherapy candidates based on human leukocyte antigen binding affinity
The objective of this descriptive study was to determine Felis domesticus (cat) and Canis familiaris (dog) protein epitopes that bind strongly to selected HLA class II alleles to identify synthetic vaccine candidate epitopes and to identify individuals/populations who are likely to respond to vaccines. FASTA amino acid sequences of experimentally validated allergenic proteins of house cat and d...
متن کامل