EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN–SL/95/77 18 September 1995 SINGLE-SHOT TEMPORAL MEASUREMENT OF SHORT X-RAY PULSES USING VERY FAST PHOTOCONDUCTIVE DETECTORS
نویسندگان
چکیده
A report on the status of the development of picosecond photoconductive detectors is presented. The main application of these devices is the single-shot temporal measurement of picosecond X-ray, UV, and visible light pulses. We compare different materials, and describe the X-ray autocorrelator and the single-shot sampler developed in the LETI (Grenoble). Submitted to the 9th International Workshop on Room Temperature Semiconductor X and Gamma Ray Detectors Associated Electronics and Applications, Grenoble, France, 18–22 September 1995
منابع مشابه
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH European Laboratory for Particle Physics CERN - SL DIVISION CERN{SL/95{79 (EA) MEASUREMENT OF PAIR{PRODUCTION BY HIGH ENERGY PHOTONS IN AN ALIGNED TUNGSTEN CRYSTAL
A new measurement has been made of the rate of pair{production in a 3.2 mm thick tungsten crystal, exposed to photons with energies in the range 10 to 150 GeV, for angles of incidence up to 10 mrad from the crystal axis. A strong enhancement of the pair{production rate is observed when the beam is aligned along the <100> crystal axis, as compared to a random orientation. This e ect can be explo...
متن کاملEUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN–ECP/95–1 January 1995 ANALOG LIGHTWAVE LINKS FOR DETECTOR FRONT-ENDS AT THE LHC
Lightwave links are being developed for volume application in the transfer of analog signals from the tracking detector front-ends to their readout electronics. The links are based on electrooptic intensity modulators mounted on detectors and connected by optical fibres to remotely located transceivers (lasers and photoreceivers). The modulators are III-V semiconductor reflective devices based ...
متن کاملEUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN SL-95-92 (AP) Shielding E ects on Coherent Synchrotron Radiation
A controversy concerning the shielding of coherent synchrotron radiation has existed for many years. Estimates of the reduction of radiated power by nearby conducting surfaces in LHC di er by several orders of magnitude when one uses the expressions given in two of the major papers in the eld. A clari cation of this problem as well as the expected values for coherent synchrotron radiation in LE...
متن کاملEUROPEAN ORGANISATION FOR NUCLEAR RESEARCH CERN-PPE/95-106 17 May 95 A HIGH RESOLUTION BEAM TELESCOPE BUILT WITH DOUBLE SIDED SILICON STRIP DETECTORS
A compact and portable beam telescope has been built using four 1.92 x 1.92 cm2 double sided silicon microstrip detectors with 50 μ m read-out pitch. Tests using 50 GeV pions have shown that the beam position can be defined with a precision of 3 μm and 6 μm on the p-side and n-side respectively with an overall detection efficiency of 93.0%. ( submitted to Nucl. Inst. and Meth. A )
متن کاملEUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN–ECP/95–10 18 May 1995 A TRANSIMPEDANCE AMPLIFIER USING A NOVEL CURRENT MODE FEEDBACK LOOP
We present a transimpedance amplifier stage based on a novel current mode feedback topology. This circuit employs NMOS and PMOS transistors exclusively and requires neither capacitor for stabilizing the transimpedance loop nor resistor for the transresistance feedback and transistor loading. This amplifier circuit is fully compatible with submicron digital CMOS processes. The active feedback ne...
متن کامل