Measurement of ventricular torsion by two-dimensional ultrasound speckle tracking imaging.

نویسندگان

  • Yuichi Notomi
  • Peter Lysyansky
  • Randolph M Setser
  • Takahiro Shiota
  • Zoran B Popović
  • Maureen G Martin-Miklovic
  • Joan A Weaver
  • Stephanie J Oryszak
  • Neil L Greenberg
  • Richard D White
  • James D Thomas
چکیده

OBJECTIVES We sought to examine the accuracy/consistency of a novel ultrasound speckle tracking imaging (STI) method for left ventricular torsion (LVtor) measurement in comparison with tagged magnetic resonance imaging (MRI) (a time-domain method similar to STI) and Doppler tissue imaging (DTI) (a velocity-based approach). BACKGROUND Left ventricular torsion from helically oriented myofibers is a key parameter of cardiac performance but is difficult to measure. Ultrasound STI is potentially suitable for measurement of angular motion because of its angle-independence. METHODS We acquired basal and apical short-axis left ventricular (LV) images in 15 patients to estimate LVtor by STI and compare it with tagged MRI and DTI. Left ventricular torsion was defined as the net difference of LV rotation at the basal and apical planes. For the STI analysis, we used high-frame (104 +/- 12 frames/s) second harmonic two-dimensional images. RESULTS Data on 13 of 15 patients were usable for STI analysis, and LVtor profile estimated by STI strongly correlated with those by tagged MRI (y = 0.95x + 0.19, r = 0.93, p < 0.0001, analyzed by repeated-measures regression models). The STI torsional velocity profile also correlated well with that by the DTI method (y = 0.79x + 2.4, r = 0.76, p < 0.0001, by repeated-measures regression models) with acceptable bias. CONCLUSIONS The STI estimation of LVtor is concordant with those analyzed by tagged MRI (data derived from tissue displacement) and also showed good agreement with those by DTI (data derived from tissue velocity). Ultrasound STI is a promising new method to assess LV torsional deformation and may make the assessment more available in clinical and research cardiology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Temperature Mapping Using Ultrasound Digital Images

Introduction:  The  success  of  hyperthermia  depends  on  the  accuracy  of  the  temperature  monitoring in the tumor and the surrounding normal tissue. In this study, the temperature changes  were determined by computing the speckle displacement in the ultrasound digital images. Speckle  tracking algorithm was used to compute the displacement.  Materials and Methods: The experiment was perf...

متن کامل

Age-Related Changes in Left Ventricular Torsion as Assessed by 2-Dimensional Ultrasound Speckle Tracking Imaging

Background and Objectives: The newly developed 2-dimensional ultrasound speckle tracking imaging (2D-STI) has enabled researchers to assess the changes of left ventricular (LV) rotation and torsion. The aims of the present study are to establish normal values and to examine the effect of advancing age on left ventricular torsion. Subjects and Methods: We enrolled 182 healthy persons in this stu...

متن کامل

The role of speckle tracking strain imaging in cardiac pacing.

In recent years, concerns have been raised about possible harmful effects of long-term right ventricular (RV) apical pacing. These detrimental effects may be related to changes in left ventricular (LV) mechanics during RV apical pacing. As a consequence, alternative RV pacing sites have been proposed, and in selected patients an upgrade from RV to biventricular pacing may be considered. Novel t...

متن کامل

Assessment of left ventricular torsion in long axis view in patients with chronic stenosis of coronary arteries

Background: Left ventricular torsion is one of the most important biomechanical parameters of heart that routinely is measured in short axis view.  A review of the literature has indicated that assessment of left ventricular torsion in short axis view has some limitations. In the present study, we evaluated whether torsion angle assessment in long axis view can be used as a diagnostic biomechan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 45 12  شماره 

صفحات  -

تاریخ انتشار 2005