Comparison of SWAP and SAP on the point of glaucoma conversion

نویسندگان

  • Ioannis Havvas
  • Dimitris Papaconstantinou
  • Marilita M Moschos
  • Panagiotis G Theodossiadis
  • Vasilios Andreanos
  • Pantelis Ekatomatis
  • Ioannis Vergados
  • Dimitrios Andreanos
چکیده

BACKGROUND The purpose of this study was to compare the two perimetric modalities, SWAP (short wavelength automated perimetry) and SAP (standard automated perimetry), on the point of conversion to glaucoma. METHODS In this prospective, longitudinal, follow-up study, 282 patients with ocular hypertension were recruited consecutively and tested with both SAP and SWAP annually for 5 years or until the onset of conversion to glaucoma. SAP and SWAP perimetry was performed with the Humphrey Field Analyzer II using the 24-2 full-threshold test. Abnormality for both SAP and SWAP fields was determined on the pattern deviation plot and defined as either a) one point below the 0.5% probability level or b) a cluster of 2 or more points below 1% or c) a cluster of 3 or more points below 2% or d) a cluster of 4 or more points below 5%. Abnormal tests had to be confirmed on a subsequent test within one year to be classified as conversion. RESULTS Of the 282 patients initially recruited, 32 were excluded. Of the 250 remaining patients, a total of 38 converted during the follow-up period; 36.8% of conversions were detected earlier with SWAP, 29% simultaneously, and 34.2% were not detected with SWAP during the follow-up period; 2.4% of patients showed SWAP visual field loss that did not result in conversion during the follow-up period. CONCLUSION The results in our study are inconclusive. There were patients with earlier, simultaneous, or no SWAP conversion, with SAP conversion as the golden standard criterion. One should consider both SAP and SWAP with confirmation when visual field loss is evident to maximize early detection of glaucoma, because it appears that each method identifies early glaucoma in a subset of patients and these subsets overlap only partially.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Standard Automated Perimetry, Short-Wavelength Automated Perimetry, and Frequency-Doubling Technology Perimetry to Monitor Glaucoma Progression

Detection of progression is paramount to the clinical management of glaucoma. Our goal is to compare the performance of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), and frequency-doubling technology (FDT) perimetry in monitoring glaucoma progression.Longitudinal data of paired SAP, SWAP, and FDT from 113 eyes with primary open-angle glaucoma enrolled in the D...

متن کامل

Comparison of standard automated perimetry, frequency-doubling technology perimetry, and short-wavelength automated perimetry for detection of glaucoma.

PURPOSE To compare the performance of standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, and short-wavelength automated perimetry (SWAP) in detecting glaucoma. METHODS One hundred thirty-two eyes of 95 glaucoma patients and 37 normal subjects had retinal nerve fiber layer (RNFL) imaging and visual field testing by SAP, Matrix FDT perimetry, and Swedish interact...

متن کامل

Correlation between Macular Thickness and Visual Field in Early Open Angle Glaucoma: A Cross-Sectional Study

The aim of this study was to correlate macular thickness and visual field parameters in early glaucoma. A total of 104 eyes affected with early glaucoma were examined in a cross-sectional, prospective study. Visual field testing using both standard automated perimetry (SAP) and shortwave automated perimetry (SWAP) was performed. Global visual field parameters, including mean deviation (MD) and ...

متن کامل

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...

متن کامل

Achromatic and short-wavelength automated perimetry in patients with glaucomatous large cups.

OBJECTIVE To evaluate visual function and optic disc features in patients with large cup-disc ratios (C/Ds). METHODS One eye of 86 patients with vertical C/Ds by contour of at least 0.8, who had undergone both standard achromatic automated perimetry (SAP) and short-wavelength automated perimetry (SWAP) testing, was selected retrospectively. Two masked glaucoma specialists independently graded...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013