Scatter-free breast imaging using a monochromator coupled to a pixellated spectroscopic detector

نویسندگان

  • M. C. Veale
  • M. D. Wilson
  • J. Scuffham
چکیده

This project uses the combination of a spectroscopic detector and a monochromator to produce scatter free images for use in mammography. Reducing scatter is vital in mammography, where typical structures have either low contrast or small dimensions. The typical method to reduce scatter is the anti-scatter grid, which has the drawback of absorbing a fraction of the primary beam as well as scattered radiation. An increase in the dose is then required in order to compensate. Compton-scattered X-rays have lower energy than the primary beam. When using a monochromatic beam and a spectroscopic detector the scattered beam will appear at lower energies than the primary beam in the detected spectrum. Therefore if the spectrum of the detected X-rays is available, the scattered component can be windowed out of the spectrum, essentially producing a scatter free image. The monochromator used in this study is made from a Highly Orientated Pyrolytic Graphite (HOPG) crystal with a mosaic spread of 0.4°±0.1°. The detector is a pixellated spectroscopic detector that is made from a 2 cm x 2 cm x 0.1 cm CdTe crystal with a pixel pitch of 250 μm and an energy resolution of 0.8 keV at 59.5 keV. This work presents the characterisation of the monochromator and initial imaging data. The work shows a contrast increase of 20% with the removal of the low energy Compton scattered X-rays.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Approach to Scatter-free Imaging for the Improvement of Breast Cancer Detection

Compton scattering is one of the main causes of image degradation in X-ray imaging. This is particularly noticeable in mammography where details of interest feature low contrast in comparison to the surrounding tissue. This work shows the feasibility of obtaining scatter-free images by using a quasimonochromatic X-ray beam and a pixellated spectroscopic detector. This work presents characterisa...

متن کامل

Scatter free imaging for the improvement of breast cancer detection in mammography.

In mammography, the reduction of scattered x-rays is vital due to the low contrast or small dimension of the details that are searched for. The typical method of doing so in current conventional mammography is the anti-scatter grid. The disadvantage of this method is the absorption of a proportion of the primary beam and therefore an increase in dose is required to compensate for the loss of co...

متن کامل

Hyperspectral X-ray imaging for scatter removal in mammography

The purpose of this study is to investigate the use of hyperspectral X-ray imaging i.e, an imaging modality where spectral information on detected X-rays is available, for the removal of scatter in mammography. Features that suggest the presence of cancer are often low in contrast or small in size and therefore a good image quality is required in order to locate them. Current mammography system...

متن کامل

K-edge subtraction imaging using a pixellated energy-resolving detector

This paper presents preliminary work aimed at assessing the feasibility of K-edge subtraction imaging using the spectroscopic information provided by a pixellated energy-resolving Cadmium Zinc Telluride detector, having an active area of 20x20 pixels 250 m in size. Images of a test object containing different amounts of Iodine-based contrast agent were formed above and below the K-edge of Iodin...

متن کامل

U . K . Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector

In this work the results on imaging and spectroscopic performances of 14×14×1 mm CdTe detectors with 55×55 μm and 110×110 μm pixel pitch bump-bonded to a Timepix chip are presented. The performance of the 110× 110 μm pixel detector was evaluated at the extreme conditions beam line I15 of the Diamond Light Source. The energy of X-rays was set between 25 and 77 keV. The beam was collimated throug...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015