Simulation of the Switching Arc for a Motor Protective Circuit Breaker

نویسنده

  • Christian Rümpler
چکیده

The electric current is omnipresent and indispensable in our life. But there are always threatening dangers connected with it. One of them is the electric short circuit and we have to protect people and facilities from its effects. This protection is often provided by power circuit breakers or motor protective circuit breakers. These devices are able to detect the short circuit, limit the current, switch it off and provide save insulation before any harm can occur. During the switching process of short circuits an electrically conductive plasma, the electric arc, exists between the metal contacts. The thermal, aerodynamic and magnetic interactions of this electric arc within the switching device are decisive for a safe current switch-off. These processes are simulated using the fi nite element code ANSYS to solve the magnetic fi eld problem and the fi nite volume code Fluent to solve the fl uid dynamics problem. Both codes are coupled using the coupling interface MpCCI. This work shows numerical results of an electric arc simulation using the example of a motor protective circuit breaker from Moeller series production. The simulation results show good agreement with experimental results. INTRODUCTION The electric current is omnipresent and indispensable in our life. It is delivering energy and allows us to operate and control a lot of applications. The simplest case of controlling is the switch-on and switch-off operation where electrical switches are required. But there are always threatening dangers connected with the electrical current. Current consumers can be overloaded, faulty equipment can be overheated and become sources of fi re. An other danger is the electric short circuit and we have to protect people and facilities from these effects. This protection is often provided by power circuit breakers or motor protective circuit breakers (Figure 1). These devices are able to detect the short circuit, limit the current, switch it off and provide save insulation before any harm can occur. EL EC TR IC A L EN G IN EE RI N G

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overvoltage Transient Analysis of Vacuum Circuit Breaker Switched Arc Furnace Installation

Frequent Switching of arc furnace in steel company causes a great effect on the insulation of arc furnace transformer winding which in turn may causes a shutdown of production for long periods of time. Therefore, it is necessary to study and analyze the causes of these outages and design an adequate protective device. In this paper the transient overvoltage resulted from vacuum circuit breaker ...

متن کامل

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...

متن کامل

Transient Minimization Within Static Var Compensated Distribution Systems

VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...

متن کامل

Dynamical simulation of a Vacuum Switch with PSCAD

The switching behavior of vacuum switches (VS) is different to that of other circuit breakers. There are several effects which have to be taken into account, for example the current chopping, the dielectric strength of vacuum gap, the arc voltage, the quenching capability of high frequency currents, virtual current chopping and prestrikes. In some earlier investigations the characteristics of v...

متن کامل

Investigating Impacts of Sustainable Repair Time and Circuit Breaker Model on Meshed Distribution Networks Reliability Assessment

Generally, the failure rate and the repair time of system components are constant parameters in reliability assessment of electric distribution systems. A failure of component is resulted from failing in the operation or overloading. In addition, there exist cases where, the repair times of components are small and tolerable from customer point of view. Thus, tolerable repair times may be overl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009