Clinical Audit of Image Quality in Radiology Using Visual Grading Characteristics Analysis.

نویسندگان

  • Erik Tesselaar
  • Nils Dahlström
  • Michael Sandborg
چکیده

The aim of this work was to assess whether an audit of clinical image quality could be efficiently implemented within a limited time frame using visual grading characteristics (VGC) analysis. Lumbar spine radiography, bedside chest radiography and abdominal CT were selected. For each examination, images were acquired or reconstructed in two ways. Twenty images per examination were assessed by 40 radiology residents using visual grading of image criteria. The results were analysed using VGC. Inter-observer reliability was assessed. The results of the visual grading analysis were consistent with expected outcomes. The inter-observer reliability was moderate to good and correlated with perceived image quality (r(2) = 0.47). The median observation time per image or image series was within 2 min. These results suggest that the use of visual grading of image criteria to assess the quality of radiographs provides a rapid method for performing an image quality audit in a clinical environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual grading characteristics (VGC) analysis: a non-parametric rank-invariant statistical method for image quality evaluation.

Visual grading of the reproduction of important anatomical structures is often used to determine clinical image quality in radiography. However, many visual grading methods incorrectly use statistical methods that require data belonging to an interval scale. The rating data from the observers in a visual grading study with multiple ratings is ordinal, meaning that non-parametric rank-invariant ...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

Visual grading characteristics and ordinal regression analysis during optimisation of CT head examinations

OBJECTIVES To evaluate visual grading characteristics (VGC) and ordinal regression analysis during head CT optimisation as a potential alternative to visual grading assessment (VGA), traditionally employed to score anatomical visualisation. METHODS Patient images (n = 66) were obtained using current and optimised imaging protocols from two CT suites: a 16-slice scanner at the national Maltese...

متن کامل

Visual grading regression: analysing data from visual grading experiments with regression models.

For visual grading experiments, which are an easy and increasingly popular way of studying image quality, hitherto used data analysis methods are often inadequate. Visual grading analysis makes assumptions that are not statistically appropriate for ordinal data, and visual grading characteristic curves are difficult to apply in more complex experimental designs. The approach proposed in this pa...

متن کامل

Characteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization

Objective(s): The aim of this study is to examine the effect of different smoothing filters on the image quality and SUVmax to achieve the guideline recommended positron emission tomography (PET) image without harmonization. Methods: We used a Biograph mCT PET scanner. A National Electrical Manufacturers Association (NEMA) the International Electrotechnical Commission (IEC) body phantom was fil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 169 1-4  شماره 

صفحات  -

تاریخ انتشار 2016