Segmentation and removal of fibrovascular membranes with high-speed 23 G transconjunctival sutureless vitrectomy, in severe proliferative diabetic retinopathy
نویسندگان
چکیده
AIM To evaluate the effectiveness and safety of high-speed (5,000 cuts per minute) 23 G transconjunctival sutureless vitrectomy (TSV) in severe diabetic fibrovascular proliferation (DFVP). PATIENTS AND METHODS In this retrospective consecutive case series, patients who underwent 23 G TSV for severe DFVP between October 2011 and March 2014 at our institution were evaluated. 23 G TSV was performed with a high-speed (5,000 cuts per minute) cutter without a chandelier light. RESULTS The mean follow-up period was 8 months (range: 4-23 months). Of the 27 eyes of 27 patients, 14 eyes (52%) underwent concomitant phacoemulsification with posterior chamber intraocular lens implantation, nine eyes (33%) were pseudophakic, and four eyes were phakic (15%). DFVP was removed with ease in all, and visual acuity was improved in 18 (67%) eyes. Iatrogenic retinal tear was observed in four eyes (15%) and treated successfully during surgery. Suture placement to a single sclerotomy was performed in eight eyes (30%). Postoperative intraocular hemorrhage was observed in five eyes (18%). Cataract formation was observed in two of the four phakic eyes. Three (11%) patients had postoperative intraocular pressure rise. Postoperative hypotony (≤6 mmHg) and endophthalmitis were not observed in any eye. CONCLUSION The segmentation and removal of fibrovascular membranes with high-speed 23 G TSV seems to be a safe and easy method in severe diabetic eye disease.
منابع مشابه
23-gauge versus 25-gauge vitrectomy for proliferative diabetic retinopathy: a comparison of surgical outcomes.
PURPOSE This study compared clinical outcomes and complications between 23-gauge (23g) and 25-gauge (25g) transconjunctival sutureless vitrectomy in patients with proliferative diabetic retinopathy. STUDY DESIGN It was a retrospective study using data prospectively defined and collected. 80 eyes underwent 23g transconjunctival sutureless vitrectomy, and 80 eyes underwent 25g surgery using the...
متن کاملAdvances in Vitreo-retinal Surgery: 23-gauge Sutureless Pars Plana Vitrectomy
Pars plana vitrectomy is one of the most common surgical procedures performed for the treatment of various vitreo-retinal diseases such as retinal detachment, vitreous haemorrhage, proliferative diabetic retinopathy, epiretinal membrane and macular hole. Traditionally, most vitrectomy surgical systems utilise the 20-gauge instruments pars plana vitrectomy includes multiple incisions including p...
متن کاملComparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
BACKGROUND To assess the rate and type of retinal break formation in patients undergoing 23 gauge transconjunctival vitrectomy surgery for complications of proliferative diabetic retinopathy compared with 20 gauge vitrectomy surgery. METHODS Retrospective case notes review of two consecutive series of patients who had primary pars plana vitrectomy for complications of proliferative diabetic r...
متن کاملWound sealing-related complications of 25-gauge vitrectomy in proliferative diabetic retinopathy versus simple macular pathology.
PURPOSE To compare the incidence of wound sealing-related complications of 25-gauge transconjunctival sutureless vitrectomy (25-G TSV) for proliferative diabetic retinopathy (PDR) versus non-diabetic simple macular pathology (SMP). METHODS A retrospective comparative study was conducted on 377 eyes that underwent 25-G TSV for PDR (n=189 eyes) or non-diabetic SMP (n=188 eyes). Both groups were...
متن کاملActive Silicone Oil Removal with a Transconjunctival Sutureless System: Is the 23-Gauge System Safe and Effective?
OBJECTIVES To evaluate the safety and efficacy of active silicone oil removal with a 23-gauge (G) transconjunctival sutureless system. MATERIALS AND METHODS One hundred sixteen eyes of 113 patients who had previous retinal detachment surgery with pars plana vitrectomy and silicone oil injection surgery, and underwent silicone oil removal surgery with 23-G transconjonctival sutureless techniqu...
متن کامل