A simple method of carbon dioxide estimation in expired air.

نویسندگان

  • J S INKSTER
  • L T REES
چکیده

A SIMPLE method for the estimation of carbon dioxide in air or gas mixtures containing anaesthetic gases finds many applications in the investigation of anaesthetic problems and in the control of artificial respiration by mechanical respirators. This adaptation of already established techniques utilizes apparatus which may be found in most hospitals. It is rapid, and can be performed at the bedside or in the operating-room. The principal has been employed for some time (Higgins and Marriott, 1917; Wilson, Orcutt and Peterson, 1932; Wilson, 1933), and has recently been adapted by Brinkman in an instrument known as the " Carbovisor". The gas mixture to be examined is brought into equilibrium with an indicator solution lightly buffered with sodium bicarbonate. The tension of carbon dioxide in the gas mixture determines the pH achieved in the buffered solution and the pH, in turn, determines the colour of the indicator. The colour of the indicator is estimated in a photo-electric colorimeter, using a convenient filter. The indicator solution consists of bromthymol blue 0.005 per cent and sodium bicarbonate 0.05 per cent and it has been found to be stable in storage provided that it is kept in bottles the interior of which have been carefully lined with paraffin wax.. The sample of gas to be analysed is drawn into a syringe with a long needle attached; 10 ml are required. The tip of the needle is then placed underneath the surface of a small quantity of the indicator solution and 2 ml of gas expelled from the syringe; 2 ml of the indicator solution are then drawn in. The syringe is then closed, either with a blanked-off needle hub or by thrusting the point of the needle into a rubber bung. The syringe and

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Psychological Concomitants of High Alveolar Carbon Dioxide

merer at various stages of his progress toward recovery. The determination of alveolar carbon dioxide is readily made by analysis of expired air. The tension, or partial pressure, of the C02 thus ascertained very closely approximates that of the arterial blood of the subject. For a prolonged research upon psychological clinical subjects, this method is obviously preferable to direct blood analy...

متن کامل

Estimation of Soil Carbon Sequestration Rate in Steppes (Case Study: Saveh Rudshur Steppes)

Since Renaissance, the natural ecosystems have fallen into a complete state ofdisarray due to the rise in the amount of carbon dioxide. Soil, the unsparing stuff, is one of themajor sources of carbon storage, and plays a paramount role in the global equilibrium ofcarbon as well as carbon sequestration. Given that Iran is benefiting from vast steppes, therate of carbon sequestration in them dese...

متن کامل

Attempts at estimating mixed venous carbon dioxide tension by the single-breath method.

The single-breath method was originally proposed by Kim et al. [1] for estimating the blood carbon dioxide tension and cardiac output. Its reliability has not been proven. The present study was undertaken, using dogs, to compare the mixed venous carbon dioxide tension (PVCO2) calculated by the single-breath method with the PVCO2 measured in mixed venous blood, and to evaluate the influence of v...

متن کامل

Evaluation of methods used to estimate inhaled dose of carbon monoxide.

We have compared estimation of alveolar carbon monoxide measured either as end-expired or mixed-expired carbon monoxide tension with two spectrophotometric estimations of venous blood carboxyhaemoglobin (COHb). Estimation of mixed-expired carbon monoxide proved more convenient for patients than the end-expired method, and this estimation of carbon monoxide exposure discriminated between non-smo...

متن کامل

CO2 Removal from Air in a Countercurrent Rotating Packed Bed, Experimental Determination of Height of Transfer Unit

Carbon dioxide capture is a key issue in climate change mitigation. For decades the removal of carbon dioxide has been an essential step in many industrial processing operations such as the synthesis of ammonia, natural gas purification, and oil refining. In this study, a rotating packed bed has been designed for absorption of carbon dioxide from an air stream. The rotating packed bed is a comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 28 1  شماره 

صفحات  -

تاریخ انتشار 1956