Truview EVO2 and Standard Macintosh Laryngoscope for Tracheal Intubation During Cardiopulmonary Resuscitation
نویسندگان
چکیده
The aim of this study was to compare the performance of the Truview EVO2 laryngoscope in manikin-simulated cardiopulmonary resuscitation (CPR) and no-CPR scenarios with standard intubation technique. Participants performed 4 scenarios in random order: endotracheal intubation (ETI) using Macintosh laryngoscope (MCL), Truview EVO2 laryngoscope in no-CPR patient scenario, and intubation during uninterrupted chest compressions using both laryngoscopes. The participants were directed to make 3 attempts in each scenario. Primary outcomes were time to tracheal intubation (TTI) and intubation success, whereas secondary outcomes were cumulative success ratio and the number of esophageal intubation (EI). TTI and success ratios were reported per attempt. Thirty paramedics completed the study. Median TTI with Truview EVO2 with CPR was 36 (interquartile range [IQR] 29.00-52.00), 22.5 (IQR 18.33-35.00), and 18 (IQR 11.00-23.00) seconds; MCL with CPR was 23 (IQR 18.92-36.90), 16.8 (IQR 14.00-22.31), and 14.5 (IQR 11.12-16.36) seconds; Truview EVO2 without CPR was 28.6 (IQR 24.02-38.34), 21.7 (IQR 17.00-25.00), and 13 (IQR 11.90-17.79) seconds; MCL without CPR was 17 (IQR 13.23-22.29), 13 (IQR 12.09-15.26), and 12.4 (IQR 10.08-19.84) seconds for first, second, and third attempts, respectively. The P values for differences in TTI between Truview EVO2 and MCL were P < 0.0001, P = 0.0540, and P = 0.7550 in CPR scenario and P = 0.0080, P = 0.1570, and P = 0.7652 in no-CPR scenario for first, second, and third attempts, respectively. The success ratios for each of the scenarios were as follows: in CPR scenario it was 0.73 versus 0.53 (P = 0.0558), 0.83 versus 0.76 (P = 0.2633), and 1 versus 0.8 (P = 0.0058); in no-CPR scenario it was 0.63 versus 0.73 (P = 0.2068), 0.86 versus 0.86, and 0.97 versus 1 (P = 0.1637) for Truview EVO2 vs MCL in first, second, and third attempts, respectively. The cumulative success ratio related to the time of ETI was better for MCL compared with Truview EVO2 laryngoscope in both scenarios (P = 0.0029 and P = 0.0004 in no-CPR and CPR scenarios). The number of EI with MCL was 30% versus 13.3% (P = 0.0113), and for Truview EVO2 it was 20.45% versus 15.56% in CPR and no-CPR scenarios, respectively. The application of Truview EVO2 during uninterrupted chest compressions increased TTI but increased the success ratio of ETI and decreased number of EIs.
منابع مشابه
An evaluation of the TruView EVO2 laryngoscope.
The TruView EVO2 laryngoscope was compared with the traditional Macintosh laryngoscope in 200 patients who required tracheal intubation for elective surgery. Mallampati score determined prior to laryngoscopy was significantly related to the view of the glottis during laryngoscopy for both laryngoscopes. The view of the larynx was better with the TruView EVO2 laryngoscope than with the Macintosh...
متن کاملA Comparative Evaluation of Truview and Macintosh Laryngoscopes for Tracheal Intubation
4,5 mortality. *Assistant Professor, **Professor, ***Associate Professor, ****Professor and Head of Dept., Lokmanya Tilak Municipal Medical College and Lokmanya Tilak Municipal General Hospital, Sion, Mumbai-400 022. Abstract Introduction: Truview EVO2 is a modified laryngoscope that provides a 42o anterior view facilitating visualisation of the glottis without alignment of oropharyngeal and tr...
متن کاملA comparison of the TruView EVO2 and macintosh laryngoscope blades
Intubation is one of the basic procedures of anesthesia. The reported frequency of difficult intubations is between 1.5% and 13%, which is a problem that requires a prompt solution. Although the likelihood of a difficult intubation can be estimated from preoperative measurements and scoring systems, obtaining direct access to the glottis during preoperative direct laryngoscopy can be difficult....
متن کاملMuscle activity during endotracheal intubation using 4 laryngoscopes (Macintosh laryngoscope, Intubrite, TruView Evo2 and King Vision) - A comparative study.
BACKGROUND Successful endotracheal intubation requires mental activity and no less important physical activity from the anesthesiologist, so ergonomics of used devices is important. The aim of our study has been to compare 4 laryngoscopes regarding an operator's activity of selected muscles of the upper limb, an operator's satisfaction with used devices and an operator's fatigue during intubati...
متن کاملComparison of the TruView infant EVO2 PCD™ and C-MAC video laryngoscopes with direct Macintosh laryngoscopy for routine tracheal intubation in infants with normal airways
OBJECTIVE Videolaryngoscopy has mainly been developed to facilitate difficult airway intubation. However, there is a lack of studies demonstrating this method's efficacy in pediatric patients. The aim of the present study was to compare the TruView infant EVO2 and the C-MAC videolaryngoscope with conventional direct Macintosh laryngoscopy in children with a bodyweight ≤10 kg in terms of intubat...
متن کامل