An investigation of the concentration dependence and response to analyte mixtures of carbon black/insulating organic polymer composite vapor detectors.
نویسندگان
چکیده
The responses relative to an air background of carbon black/polymer composite vapor detectors have been determined as a function of the concentration of a homologous series of alcohols (n-CnH2n+1OH, 1 < or = n < or = 8), a homologous series of alkanes (n-CnH2n+2, 5 < or = n < or = 10 and n = 12, 14), and a set of diverse solvent vapors. In all cases, the steady-state relative differential resistance responses, delta R/Rb, of the carbon black/polymer composite vapor detectors were well-described by a linear relationship with respect to the analyte partial pressure, at least over the tested concentration range (P/P degree = 0.005-0.03, where P degree is the vapor pressure of the analyte). When two vapors in air were simultaneously presented to the detectors, the delta R/Rb response, relative to an air background, was the sum of the delta R/Rb values obtained when each analyte was exposed separately to the carbon black/polymer composite detectors under study. Similarly, when an analyte was exposed to the detectors on top of a background level of another analyte, the delta R/Rb values of the array of detectors were very close to those obtained when the test analyte was exposed to the detectors only in the presence of background air. The initial training requirements from the array response output data of such detectors are minimized because the delta R/Rb response pattern produced by the analyte of concern can be associated uniquely with that odor, under the conditions explored in this work.
منابع مشابه
Array-Based Vapor Sensing Using - Chemically Sensitive, Polymer Composite Resistors
We describe herein the construction of simple, low-power, broadly responsive vapor sensors. Insulating polymer-conductor composites have been shown to swell reversibly upon exposure to vapors. Thin films of polymer composites have been deposited across two metallic leads, with swelling-induced resistance changes of the films signaling the presence of vapors. To identify and classify vapors, arr...
متن کاملDetection and classification characteristics of arrays of carbon black/organic polymer composite chemiresistive vapor detectors for the nerve agent simulants dimethylmethylphosphonate and diisopropylmethylphosponate.
Arrays of conducting polymer composite vapor detectors have been evaluated for performance in the presence of the nerve agent simulants dimethylmethylphosphonate (DMMP) and diisopropylmethylphosponate (DIMP). Limits of detection for DMMP on unoptimized carbon black/ organic polymer composite vapor detectors in laboratory air were estimated to be 0.047-0.24 mg m(-3). These values are lower than ...
متن کاملCombinatorial approaches to the synthesis of vapor detector arrays for use in an electronic nose.
The technology of “electronic noses”, i.e., devices that functionally mimic the sense of olfaction, is rapidly evolving, driven by the practical demand for objective analysis of odors as well as by the intellectual challenge of mimicking the mammalian sense of olfaction.1-3 Numerous implementations of artificial noses have emerged; however, the most prevalent devices are based on detecting a ph...
متن کاملField-Structured Chemiresistors
We have developed a significantly improved chemiresistor for sensing volatile organic compounds that consists of Au-coated Ni particles organized into electrically conducting pathways in a polymer matrix by a magnetic field [1]. This sensor overcomes the problems inherent to conventional carbon-black chemiresistors, while achieving an unprecedented magnitude of response. When exposed to chemica...
متن کاملMolecular modeling of polymer composite-analyte interactions in electronic nose sensors.
We report a molecular modeling study to investigate the polymer-carbon black (CB) composite-analyte interactions in resistive sensors. These sensors comprise the JPL electronic nose (ENose) sensing array developed for monitoring breathing air in human habitats. The polymer in the composite is modeled based on its stereoisomerism and sequence isomerism, while the CB is modeled as uncharged napht...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 72 4 شماره
صفحات -
تاریخ انتشار 2000