In Vivo Determination of Femoral Head Loci Pathways During Gait In Subjects Having Either A Metal-On-Metal or Metal-On Polyethylene THA
نویسندگان
چکیده
Twenty subjects were analyzed in vivo using video fluoroscopy. Ten subjects had a metal-on-metal (MOM) THA and ten subjects had a metal-on-polyethylene (MOP) THA. All THA subjects were implanted by the same surgeon and judged clinically successful (Harris hip scores >94.0). Each subject performed normal gait while under frontal fluoroscopic surveillance. The two-dimensional (2D) fluoroscopic videos were converted into 3D using a computer automated model-fitting technique (Figure 1) (Sarojak, 1998). Five distinct femoral head positions were defined in the femoral head reference frame and transformed in the acetabular cup reference frame. At various flexion angles, these five loci positions were located, tracked and plotted with respect to flexion angle and time (Figure 2). In Vivo Determination of Femoral Head Loci Pathways During Gait In Subjects Having Either A Metal-On-Metal or Metal-On Polyethylene THA
منابع مشابه
Metallosis after Exchange of the Femoral Head and Liner following Ceramic Acetabular Liner Dissociation in Total Hip Arthroplasty with a Modular Layered Acetabular Component
The type of bearing material that should be used in revision surgery after the failure of ceramic-on-ceramic total hip arthroplasty (THA) remains controversial. In the case of ceramic fracture, the residual ceramic particles can cause consequent metallosis when metal implants are used for revision THA. On the other hand, in the case of THA failure without ceramic fracture, revision THA with a m...
متن کاملCompression of the Femoral Vessels by a Pseudotumor after Metal-on-Metal Total Hip Arthroplasty
Here we present a case of pseudotumor following total hip arthroplasty (THA) that resulted in a circulatory disturbance caused by compression of the femoral vasculature. A 63-year-old man presented with pain, swelling, and redness of the left leg 5 years after primary metal-on-metal THA using the AML-Plus stem, Pinnacle® acetabular cup, and 36 mm diameter Ultamet™ metal head system (DePuy Ortho...
متن کاملPseudotumor associated with metal-on-polyethylene total hip arthroplasty.
This case report details the presentation, imaging results, and operative findings of a pseudotumor associated with a press-fit metal-on-polyethylene total hip arthroplasty (THA). An 80-year-old man presented approximately 7 years after undergoing THA with worsening right groin and lateral hip pain with an associated proximal thigh mass. Physical examination demonstrated a tender, large anterol...
متن کاملInfluence of the femoral head size on early postoperative gait restoration after total hip arthroplasty.
BACKGROUND We investigated the effects of using large-diameter femoral heads in total hip prostheses on early postoperative gait restoration in patients undergoing total hip arthroplasty (THA). METHODS We collected data for 19 primary THAs using 28-mm metal-on-polyethylene heads (conventional group) and for 12 THAs (BHR group) using metal-on-metal femoral heads with an average size of 45 mm (...
متن کاملFatal Cobalt Toxicity after a Non-Metal-on-Metal Total Hip Arthroplasty
This case illustrates the potential for systemic cobalt toxicity in non-metal-on-metal bearings and its potentially devastating consequences. We present a 71-year-old male with grinding sensations in his right hip following ceramic-on-ceramic total hip arthroplasty (THA). After diagnosing a fractured ceramic liner, the hip prosthesis was revised into a metal-on-polyethylene bearing. At one year...
متن کامل