Nuclear arthrography: combined scintigraphic and radiographic procedure for diagnosis of total hip prosthesis loosening.
نویسندگان
چکیده
UNLABELLED Radiographic arthrography and bone scintigraphy are common diagnostic procedures used for evaluating total hip prostheses. In this study, both techniques are combined, and nuclear contrast imaging (nuclear arthrography) is added. The efficacy of the procedures is evaluated. METHODS After intravenous injection of 99mTc-methylene diphosphonate (MDP), standard radiographic arthrography was performed in 105 patients (107 prostheses). The radiographic contrast medium was mixed with insoluble 111In-colloid (5 MBq/20 ml). After completion of the radiographic arthrography, nuclear arthrography was performed, and multiple-view dualisotope images (111In, 247-keV peak only) were recorded. Images were interpreted by superposition of the 111In image and the corresponding 99mTc-MDP image, the latter serving as a landmark for the position of the prosthesis and osseous structures. Findings at surgery were used as the gold standard. RESULTS In both cemented and uncemented acetabular and femoral components, nuclear arthrography performed better than or equal to radiographic arthrography (70%-90% and 60%-75%, respectively). Nuclear arthrography had higher diagnostic accuracy than 99mTc-MDP images alone. CONCLUSION Nuclear arthrography is a sensitive technique for detection of loosening of prostheses, offering added value over radiographic arthrography and bone scanning alone, especially for evaluation of the femoral component. Radiographic arthrography remains necessary not only for adequate deposition of contrast agents but also for detailed evaluation of osseous structures.
منابع مشابه
The Diagnostic Accuracy of Radionuclide Arthrography for Prosthetic Loosening in Hip and Knee Arthroplasty
PURPOSE OF STUDY Diagnosis of prosthetic loosening in hip and knee arthroplasty remains a challenge. Although there are a number of diagnostic tools, no single test or combination is 100% sensitive or specific. There has been a recent interest in the use of radionuclide arthrography (RNA) for detection of prosthetic loosening. METHODS A retrospective review of 45 consecutive RNA scans from 20...
متن کاملAccuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis.
In this meta-analysis we included 32 English-language articles published between January 1975 and June 2004 on the diagnostic performance of plain radiography, subtraction arthrography, nuclear arthrography and bone scintigraphy in detecting aseptic loosening of the femoral component, using criteria based on the Cochrane systematic review of screening and diagnostic tests. The mean sensitivity ...
متن کاملClinical significance of additional lateral imaging in diagnosis of prosthesis infection by combined Tc-99m labeled leukocyte/bone marrow scintigraphy
Introduction: Recently the most accurate diagnostic method in the diagnosis of prosthesis infection is the combination of Tc-99m labeled leukocyte/bone marrow imaging. However the diagnostic efficiency of the test is influenced because of its low spatial resolution. Recently SPECT/CT imaging is implicated in this test with efficient additional diagnostic improvement. In the dep...
متن کاملArthrography in loosened hip prostheses. Assessment of possibilities for intra-articular therapy.
BACKGROUND Loosening is a major complication in prosthesis surgery. Less invasive alternatives to revision surgery are required to prevent and treat prosthesis loosening. Some experimental therapies investigating alternative treatments exploit the intra-articular space as a route of administration. For efficient, local delivery of therapeutic agents a contained joint space is required. Furtherm...
متن کاملThe use of 99mTc-recombinant human annexin V imaging for differential diagnosis of aseptic loosening and low-grade infection in hip and knee prostheses.
UNLABELLED The aim of this study was to assess the pattern of annexin V uptake in hip and knee prostheses suspected of being infected. METHODS A total of 7 patients undergoing revision surgery for hip or knee prostheses were studied; 5 patients had total hip replacements, and 2 had total knee replacements. Infection was confirmed by pathology, culture results, laboratory evaluation, and clini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 37 1 شماره