The evaluation of two rotary instrumentation techniques under “operator-related variables” standardized conditions

نویسندگان

  • Ozgur Uzun
  • Ozgur Topuz
  • Fatma Yalpi
  • Feyza Unsal
  • Cumhur Aydin
  • Emre Bodrumlu
چکیده

OBJECTIVE We aimed here to evaluate the enlargement characteristics of two nickel-titanium rotary instrument systems that use two different preparation techniques, in simulated root canals under "operator-related variables" standardized conditions. MATERIALS AND METHODS A total of 40 simulated canals in resin blocks were divided into two groups as the Mtwo group for use with a single-length technique and the ProTaper instrument system group for use with crown down technique. To standardize the operator-related variables, all preparations were carried out with a computer controlled device that was developed and used previously as described in a published study. The pre- and post-operative digital images of the canals were superimposed and measured at 11 levels from the apical tip. The distances between the pre- and post-operative outer lines of the root canals were measured at both the inner and outer sides of the curve. The amount of removed material and the symmetry of the preparations were evaluated. Statistical analyses were performed with Mann-Whitney test. RESULTS Significantly more material was removed by Mtwo at 9 levels and by ProTaper at 2 levels (P < 0.05) while no significant difference was determined at 11 levels. The preparations made with ProTaper were more symmetrical at 4 levels while no significant difference was determined at 7 levels. CONCLUSION Mtwo removed significantly more material than ProTaper at different levels of the curved root canals. Mtwo and ProTaper made symmetrical preparations and maintained the original shape of the root canal at different levels under controlled operator-related variables.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment

Comparison of remaining obturating material on canal walls using rotary and hand instrumentation techniques for endodontic re-treatment Dr. J. Ghoddusi*- Dr. P. Ghaziani*- Dr. Sh. Nazari** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. **Assistant Professor of Endodontics Dept., Faculty of Dentistry, Hamedan University of Medical Science...

متن کامل

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study)

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study) Dr. MH. Zarabi* - Dr. H. Djafarzadeh** - Dr. M. Bidar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Endodontist. Background and Aim: Various kinds of hand or rotary te...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

Scanning electron microscopic evaluation of root-end preparations.

The use of an ultrasonic apical preparation technique has been advocated recently. Root-end preparations in 30 extracted single-canaled human teeth were evaluated, comparing those prepared with ultrasonic instrumentation alone, or in combination with rotary bur preparation, to those prepared with rotary instrumentation alone. Specimens were evaluated for the presence of debris, smear layer, and...

متن کامل

بررسی مشکلات آماده سازی کانال با وسائل دستی و چرخشی نیکل تیتانیوم

Background and Aim: Maintaining the original canal path and safety of canal preparation during instrumentation in curved canals have been subjected to many challenges. The aim of this study was to compare several parameters of root canal preparation using flexmaster rotary and hand used Nickel-Titanium instruments. Materials and Methods: In this experimental study, sixty extracted human teeth w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2013