The Effects of Sample Matrices on Immunoassays to Detect Microcystin-LR in Water
نویسندگان
چکیده
Immunoassays are widely used biochemical techniques to detect microcystins in environmental samples. The use of immunoassays for the detection of microcystins is vulnerable to matrix components and other interferents. This study is an evaluation of the effects of interfering substances commonly found in drinking and ambient water samples using commercially-available immunoassay kits for microcystin toxins. The microplate and strip test immunoassay formats were tested in the study. For the microplate ELISA, the following were found to inhibit microcystin-LR (MC-LR) detection: 250 μg/mL Ca or Mg, 0.01% ascorbic acid, 0.1% EDTA chelating agent, 0.05 M glycine-HCl, pH 3. The following exhibited no effect: sodium chloride (NaCl, 1% to 4%) and sodium thiosulfate (0.001% and 0.01%), 0.01 to 0.1 M phosphate buffers (PB), pH 7 and 0.067 M PB at pH 5, 6, 7 and 8. Overall, up to 50 μg/mL of standard and reference natural organic matter (NOM) from various sources did not interfere in the assay system (without MC-LR) but diminished the detection of MC-LR at varying degrees. This is the first study evaluating standard and reference humic and fulvic acids from various sources in immunoassays for microcystins. The strip test also showed variable effects on MC-LR detection in the presence of NOM. This assay format was also sensitive to varying pHs and ionic strengths. MC-LR binding was inhibited at low pH (0.05 M glycine-HCl, pH 3), whereas, 0.067 M PB with pH 6, 7 and 8 can yield false positive results. Lower ionic strength of 0.01 M PB, pH 7 showed no interference in MC-LR binding whereas higher ionic strengths can interfere with MC-LR detection. NaCl at 3% and 4% can interfere with the analysis giving false positive results. Mg at 50 and 250 μg/mL showed no effect on the analysis while the same concentration of Ca can yield false positive results. The performance in marine, brackish and hard waters should be tested given the potential sensitivity to salinity. Results of this study may assist in the further refinement of existing assays and the development of practical antibody-based methods to clean-up samples and detect cyanotoxins in water.
منابع مشابه
Microcystin-LR: Effects on Freshwater Catfish Heteropneustes fossilis Prolactin Cells
Background: Previous studies have been reported on the toxicity of Microcystin-LR, which is produced by cyanobacterial growth in fish, such as Heteropneustes fossilis (H. fossilis). However, no studies have been conducted on the effects of Microcystin-LR on the prolactin cells of H. fossilis. Methods: H. fossilis fish were intraperitoneally injected with Microcystin-LR (2.5μg/25g) and sacrif...
متن کاملOptimization and Modeling of Microcystin-LR Degradation by TiO2 Photocatalyst Using Response Surface Methodology
Introduction: Microcystin-leucine arginine (MC-LR) is a toxin with harmful effects on the liver, kidney, heart, and gastrointestinal tract. So, effective removal of MC-LR from water resources is of great importance. The aim of this study was to remove microcystin-LR (MC-LR) from aqueous solution by Titanium Dioxide (TiO2). Materials and Methods: In the present study, TiO2, as a semiconductor, ...
متن کاملDetermination of microcystin-LR in surface water by a magnetic bead-based colorimetric immunoassay using antibody-conjugated gold nanoparticles
Herein we describe the development of a homogeneous competitive colorimetric immunoassay using antigen-functionalized magnetic beads (MBs) and antibody-immobilized gold nanoparticles (AuNPs) combined with the established gold staining method for the determination of microcystin-leucinearginine (MC-LR) in surface water. Solid phase extraction proved to be the most beneficial sample preparation m...
متن کاملDetermination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.
A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved...
متن کاملVariations in the Microcystin Content of Different Fish Species Collected from a Eutrophic Lake
Microcystins produced from cyanobacteria can accumulate in fish tissues. Liquid chromatography coupled with tandem quadrupole mass spectrometry (LC-MS/MS) is an attractive alternative to immunoassays for the determination of low concentrations of microcystins in tissues. Fish taken from Grand Lake St. Marys, a eutrophic lake in Ohio, USA, were analyzed for microcystin-LR in their fillets using ...
متن کامل