New analysis method for CCD X-ray data

نویسندگان

  • T. Ishiwatari
  • J. Zmeskal
چکیده

The analysis method developed for kaonic nitrogen X-ray data obtained at the DAFNE electron–positron collider of Frascati National Laboratories using Charge-Coupled Devices (CCDs) in the DEAR experimental setup is described. Background events could be highly rejected by this analysis procedure. Three sequential X-ray lines from kaonic nitrogen transitions, showing good energy resolution, could be clearly identified, and the yields measured for the first time. PACS: 36.10.Gv; 14.40.Aq; 29.30.Kv

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral classification of sources in XMM-Newton X-ray observation of the rapidly accreting young star V1647 Ori

The XMM-Newton observatory is collecting a tremendous amount of X-ray imaging spectroscopy data. To deal with this huge volume of data, we are investigating more efficient methods to classify astronomical sources based purely on their X-ray spectra, and to understand the fundamental physical mechanisms responsible for X-ray emission. Multivariate statistics and pattern classification techniques...

متن کامل

A sol-gel based method for preparation of Ni/La-Al2O3 as a new catalyst for dechlorination of monochlorobenzene

In this study, two new Ni/La-Al2O3 catalysts were prepared by a sol-gel method, with different aluminium precursors (aluminium triisopropoxide and aluminium nitrate). The catalysts were characterized by scanning electron microscope (SEM), X-ray fluorescence (XRF), X-ray diffraction (XRD), BET specific surface area, and particle size analysis (PSA) techniques. The BET results showed that the par...

متن کامل

Improved Western blot detection using CCD digital imaging: Comparison of cooled-CCD digital imaging versus X-ray film

Chemiluminescent Western blotting is a popular protein detection method for studying proteins. The typical protocol for measuring chemiluminescent signal exposes the Western blot to laboratory-grade X-ray film, but digital imaging using a cooled-CCD camera is proving to be a more functional choice for researchers. The Thermo Scientific MYECL Imager offers digital imaging with a number of improv...

متن کامل

The effects of cosmic ray filtering on low intensity X-ray CCD data

Various methods exist to filter cosmic rays from X-ray CCD images with weak X-ray spectra. Distortions of the characteristics of a spectral profile such as peak centroid and relative integrated peak intensities must be kept to a minimum. Optimum methods are those minimising error bars and widths on the final centroid determination and on relative intensities which remain consistent with the wid...

متن کامل

Energetic Interactions Within the Solid - Statg Spectrometer of the ASCA Satellite

ASCA is a broad band (0.3 12 keV) x-ray astrophysical observatory in which various instruments operate with high throughput and high spectral resolution. Detailed examination of the method in which photoelectronic interactions occur in the Charge Coupled Devices (CCDs) of the Solid-State Imaging Spectrometer (SIS) on ASCA reveals a sudden variation in the nearly linear CCD signal output versus ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006