Prediction of the air temperature and humidity at the outlet of a cooling coil using neural networks

نویسندگان

  • K. Suleyman Yigit
  • H. Metin Ertunc
چکیده

The main objective of this study is to predict air temperature and humidity at the outlet of a wire-on-tube type heat exchanger using neural networks. For this purpose, initially the heat exchanger was coupled to a refrigeration unit and placed in a wind tunnel. Afterwards, its performance was tested under various experimental conditions. We measured nine input parameters, namely, temperature and humidity of the air entering the coil, air velocity, frost weight, the temperature at the coil surface, mass flow rate of the heat transfer fluid and its temperatures at the inlet and outlet of the coil along with ambient temperature. Additionally, we measured temperature and humidity of the air leaving the coil as the output parameters. Then, a feed-forward neural network based on backpropagation algorithm was developed to model the thermal performance of the coil. The artificial neural network (ANN) was trained using the experimental data to predict the air conditions at the outlet of the coil. The predicted values are found to be in good agreement with the actual values from the experiments with mean relative errors less than 1% for outlet air temperature and 2% for outlet humidity. This demonstrates that the neural network presented can help the manufacturer predict the performance of cooling coils in air-conditioning systems under various operating conditions. © 2006 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy comparison of Elamn and Jordan artificial neural networks for air particular matter concentration (PM 10) prediction using MODIS satellite images, a case study of Ahvaz.

Due to the complexity of air pollution action, artificial intelligence models specifically, neural networks are utilized to simulate air pollution. So far, numerous artificial neural network models have been used to estimate the concentration of atmospheric PMs. These models have had different accuracies that scholars are constantly exceed their efficiency using numerous parameters. The current...

متن کامل

An investigation of heat and mass transfer enhancement of air dehumidification with addition of γ-Al2O3 nano-particles to liquid desiccant

This study introduces an experimental and theoretical investigation of the performance of a proposed air dehumidification system using a nanofluid of γ-alumina nano-particles in LiBr/H2O as a desiccant. Comparative experiments organized using a central composite design were carried out to evaluate the effects of six numerical factors (air velocity, desiccant flow rate, air humidity ratio, desic...

متن کامل

An adaptive estimation method to predict thermal comfort indices man using car classification neural deep belief

Human thermal comfort and discomfort of many experimental and theoretical indices are calculated using the input data the indicator of climatic elements are such as wind speed, temperature, humidity, solar radiation, etc. The daily data of temperature، wind speed، relative humidity، and cloudiness between the years 1382-1392 were used. In the First step، Tmrt parameter was calculated in the Ray...

متن کامل

Computerized Simulation of Automotive Air-Conditioning System: Development of Mathematical Model and Its Validation

A semi-empirical model for simulating thermal and energy performance of an automotive air-conditioning (AAC) system in passenger vehicles has been developed. The model consists of two sections, namely empirical evaporator correlations and dynamic load simulation. The correlations used consider sensible and latent heat transfer performance of the evaporator coil. The correlations were obtained f...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006